S5/S7-TimeServer




Time for PLC and network +++ NTP-time-server +++ Time in S5-PLC/S7-PLC +++ Network time-server
GPS-time for S5-/S7-PLC + NTP-server
(Europe-wide LTE-modem integrated)
- GPS-time for S5-PLC, S7-PLC and NTP-server in one device
- Time directly into the PLC or in a DB of the PLC (PLC dependent)
- NTP-time-server for connected network
- No SIM-cards/contracts required for operation
- Universally applicable:
more...
ARTNR: 9367-TimeServer-EUROPE
S5/S7-TimeServer with europe-wide LTE
Obsolete
Successor: Art.No: 9354-CONNECT-HS-TSERVER
EAN number: | 4260721031066 | |
HS-code: | 85176200 | |
Weight: | 0.5 kg |
- GPS-time for S5-PLC, S7-PLC and NTP-server in one device
- Time directly into the PLC or in a DB of the PLC (PLC dependent)
- NTP-time-server for connected network
- No SIM-cards/contracts required for operation
- Universally applicable:
- S5-SPS over S5-LAN++
- S7-300/400 over S7-LAN or CP343-1/443-1
- S7-1x00 over ProfiNet
- GPS-receiver (cable length 3m) scope of delivery
- Quick and easy installation
- Input-voltage-range 9 to 30V (also use in vehicles)
- Passive PoE on LAN1 (9-30V DC)
- Wall and table mounting, DIN-rail adapter optional

Do you need the exact time in the system/control, for example for production-documentation? Or summer/winter-time changeover, everyone is still familiar with this catchphrase. Always in March and October the problem of the time-change on the PLCs of your system(s). S5/S7-TimeServer receives the time via GPS-data and then sets this directly in the S7-controllers (where possible) or in all controllers in a defined data-block. In this way, these controllers can get the time/date from it and process it. At the same time, S5/S7-TimeServer can also work as an NTP-server in your network.
Supply voltage: | 9 - 30V DC |
Power consumption: | 7 Watt |
Display: |
WebBrowser Status LEDs |
Handling/Configuration: | WEB-Browser |
Interfaces: |
4 x 10/100BaseTX RJ45-ethernet-plug auto-MDI/MDIX (3x LAN, 1x WAN) 1x Antenna-connector SMA(f) GNSS-receiver |
Operating temperature: | -40 - 75°C |
Case: | Metal-housing, suitable for table- or wall-mounting |
Dimensions: | 106 x 80 x 46 mm |
Scope of delivery: |
9367-TimeServer Plug-in power supply 230V AC => 9V DC GNSS antenna (SMA (m), 3 m cable) |
accessories:
S5-LAN++
Industrial Ethernet <> S5 PD-interface (TTY) Including Gateway Plus and S7-TCP / IP functions

plus VAT. and shipping
S7-LAN connector for Siemens S7 PLC controller Obsolete
Successor: S7-LAN++ connector for Siemens S7 Controller (Art.No: 9352-LANCON++)
Network-connection for the S7-200/300/400-PLC +++ S7-adapter PPI/MPI/PROFIBUS +++ Of developer and manufacturer +++ Smallest Ethernet-gateway S7 +++ Network for each S7-PLC +++ Fast commissioning +++ Replacement for CP343-1/443-1

plus VAT. and shipping
plus VAT. and shipping
Patch-cable 3m, Cat5+, shielded
RJ45 plug <=> RJ45 plug, 1:1
Patch-cable 0.25m, Cat5e, shielded
RJ45 plug <=> RJ45 plug, 1:1

Time

DCF-time reception for the PLC via digital I/O

reception of DCF-signals

Prepares your weak or not clean DCF signals