S7-LAN++
S7-LAN++ Connector with integrated firewall for Siemens S7-PLCs
integrated access-protection LAN <=> bus-side
- IP-address-filter
- MAC-filter
- read/write protection of individual variables,
inputs/outputs, blocks
Display of the S7-diagnostics-buffer in the
webbrowser
(no Simatic Manager/TIA Portal required)
increased performance/data throughput (up to
300%) like S7-LAN module
up to 32 parallel connections
ARTNR: 9352-LANCON++
S7-LAN++ connector for Siemens S7 Controller
EAN number: | 4260721031257 | |
HS-code: | 85423190 | |
Weight: | 0.06 kg |
S7
PPI-Bus | |||||||||
PPI 9.6 KBit/s - 19.2 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
Multimaster 9.6 KBit/s - 187.5 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
MPI-Bus | |||||||||
19.2 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
187.5 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
1.5 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
Profibus | |||||||||
9.6 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
19.2 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
45.45 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
93.75 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
187.5 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
500 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
1.5 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
3.0 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
6.0 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
12.0 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
Profibus-profile | |||||||||
DP |
x(12)
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
standard |
x(12)
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
universal(DP/FMS) |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
RS 232 | |||||||||
9.6 KBit/s |
x(19)
|
x(19)
|
|||||||
19.2 KBit/s |
x
|
x
|
|||||||
38.4 KBit/s |
x
|
x
|
|||||||
57.6 KBit/s |
x(9)
|
x(9)
|
|||||||
115.2 KBit/s |
x(9)
|
x(9)
|
|||||||
USB | |||||||||
USB 1.1 (6) |
x(1)
|
x
|
x(2)
|
||||||
LAN | |||||||||
10/100BaseTx |
x(7)
|
x
|
x
|
x
|
x
|
||||
WIFI | |||||||||
2.4 GHz |
x
|
||||||||
TeleService operation | |||||||||
with S7-300/400 |
x(14)(18)
|
x(14)(18)
|
|||||||
baud rates at TS-operation directly at the PC | |||||||||
9.6 KBit/s |
x
|
x
|
|||||||
19.2 KBit/s |
x
|
x
|
|||||||
38.4 KBit/s |
x(8)
|
x(8)
|
|||||||
57.6 KBit/s |
x(8)
|
x(8)
|
|||||||
baud rates at TS-operation directly with a modem | |||||||||
9.6 KBit/s |
x
|
x
|
|||||||
19.2 KBit/s |
x
|
x
|
|||||||
38.4 KBit/s |
x
|
x
|
|||||||
57.6 KBit/s |
x
|
x
|
|||||||
115.2 KBit/s |
x
|
x
|
|||||||
HMI | |||||||||
9.6 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
19.2 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
38.4 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
57.6 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
115.2 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
update | |||||||||
firmware-update |
x(10)
|
x(10)
|
x(15)
|
x(15)
|
x(15)
|
x(15)
|
x(15)
|
x(15)
|
x(15)
|
input/online help | |||||||||
keypad |
x
|
x
|
x
|
x(21)
|
x(21)
|
x(21)
|
x(21)
|
||
display |
x
|
x
|
x
|
x
|
x(21)
|
x(21)
|
x(21)
|
x(21)
|
|
PD connections (maximum) | |||||||||
PLCVCOM |
1
|
1
|
1
|
1
|
1
|
1
|
1
|
1
|
|
RFC1006 |
8
|
8
|
32
|
32
|
32
|
||||
AG connections (maximum) | |||||||||
passive subscriber |
1
|
15
|
15
|
15
|
15
|
15
|
15
|
15
|
15
|
active subscriber |
126
|
126
|
126
|
126
|
126
|
126
|
126
|
126
|
126
|
more functions | |||||||||
integrated PLC-firewall |
|
|
x
|
x
|
x
|
||||
display diagnostic-buffer in the webbrowser |
|
|
x
|
x
|
x
|
||||
webserver for configuration |
x
|
x
|
x
|
x
|
x
|
||||
Remote access over existing VPN-channel |
x
|
x
|
x
|
x
|
x
|
||||
Access via existing WLAN-channel |
x
|
x
|
x
|
x
|
x
|
||||
status/control variable |
x
|
x
|
x
|
x
|
x
|
||||
S7 on S7/S5 DB exchange |
x
|
x
|
x
|
x
|
x
|
||||
S5 on MPI DB exchange |
only as S5toMPI
|
||||||||
S7 on MPI (Send/Fetch) |
x
|
x
|
x
|
x
|
x
|
||||
Profinet Gateway |
x
|
x
|
x
|
x
|
x
|
||||
Time in PLC from NTP-server |
x
|
x
|
x
|
x
|
x
|
||||
galvanic separation | |||||||||
to the bus (screen connected through) |
1KV
|
1KV
|
1KV
|
1,5KV
|
1KV
|
1,5KV
|
1,5KV
|
1,5KV
|
1,5KV
|
mounting | |||||||||
wall monuting (with opt. wall mounting-set) |
x
|
x
|
x
|
x
|
|||||
upgrading with | |||||||||
CheapConn+cable |
x
|
x
|
x
|
x
|
|||||
supports | |||||||||
WIN 98 |
x
|
x(3)
|
x
|
x
|
x
|
x
|
x
|
||
WIN 98 SE |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
WIN ME |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
WIN NT |
x
|
x(5)
|
x(5)
|
x
|
x(5)
|
||||
WIN 2000 |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
WIN XP Home (4) |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
WIN XP Professional |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
Vista(32bit) |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
Win7(32bit) |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
Win7(64bit) |
(22)
|
x(23)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
Win8/8.1 |
(22)
|
x(23)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
Win10 |
(22)
|
x(23)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
Win11 |
(22)
|
x(23)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
(1) just with USB-cable plug <-> plug, type A <-> A, item number: 9352.1 (2) just with USB-cable plug <-> plug, type A <-> mini B, item number: 9352.3 (3) only serial communication (4) Siemens Step7 V5.2 and higher dont run with this operationing system (5) USB-communication is only possible with the special driver for Win NT (6) USB 2.0 is backward compatible to 1.1 (7) Cable is designed for direct connection to PC network card socket. It can also be a hub / switch with uplink port or operated at a hub / switch with automatic detection of assignement and adaptation (8) only in combination with the MPI-Speed-driver („continously-active“) (9) Siemens Step7 supports these baud rates only with the MPI-Speed-Utility (10) Update directly with PC or via Tele-Network if the cable is connected to a device of the Tele-Network-family (Tele-Link, Tele-Book or Tele-Professional) (11) only in the mode: MultiMaster-Mode (12) up to a maximum baud rate of 187.5 KBit/s (13) In this transmission, the baud rate is irrelevant, because it communicates via a virtual COM-port. (14) with the use of the TS-adapter / item number: 9350.TS (15) Update directly with PC and TIC-driver (18) Operation requires Step 7 with additional software Tele-Service (TS) from Siemens (19) only at PPI-communication possible (20) Only with TIC-driver (21) with integrated webserver possible (22) No support of Siemens Step7-software possible (23) Only with USB and with TIC-driver |
The IP filter is used to determine whether or not the entered IP-addresses or IP-address-ranges may communicate
with the connected controllers via the module.
The list can be edited centrally be switched with a button from "allowed" on "not allowed".
With the management of the data-areas it is determined whether the entered data-areas can be read/written
via the module with the connected controllers. A central button for the function determines whether the
specified inputs are "allowed" or "not allowed" are.
The input itself is kept very simple: "r" for reading and "w" for writing, a ":"
as a separator and then the data-area in S7-format. If there is only one CPU on the bus, the CPU-address
does not even have to be specified, the participant on which the module is plugged in is used.
Via the connection-menu and the included bus-device-display, it is possible to display the diagnostics
buffer of the respective device without having to open Simatic-Manager or TIA-Portal separately.
The data received from the module is output directly in one piece without the hassle of changing
tabs. All data at a glance.
Supply voltage: | 24V DC +/- 20% |
Power consumption: | 2 watt |
Display: |
Web-Browser 2 status-LEDs |
Handling/Configuration: |
Web-Browser TIC-Software |
Interfaces: |
to the PLC:
PPI/MPI/Profibus interface: 9,6 KBd - 12 MBd
to the PD/PC:
PD/diagnosis jack10/100BaseTX RJ45-ethernet jack (auto select) |
Galvanic separation: | 1500V PPI/MPI/Profibus to the PC |
Operating systems: | MS-Windows NT, 2000, XP, Vista / Win7/8/10/11 32/64 Bit |
Protocols: | RFC1006, DHCP, HTTP |
Operating temperature: | 0 - 55°C |
Case: | ABS-plastic case |
Dimensions: | 65 x 43 x 17 mm |
Scope of delivery: |
S7-LAN++-module Power connector 2pins small |
accessories:
plus VAT. and shipping
USB-powercable for 24V DC, max. 3W
USB-plug type A to 2 open braids 24V DC, maximum current: 125mA (for PC 100mA) length: 5m
plus VAT. and shipping
plus VAT. and shipping
Cross-cable 3m Cat5+, shielded
RJ45 plug <=> RJ45 plug, twisted pinning
Patch-cable 3m, Cat5+, shielded
RJ45 plug <=> RJ45 plug, 1:1
plus VAT. and shipping
S7-bus-coupler
Disconnects all signals except differential bus lines Safety for all participants at VIPA 21x-2BM0x and 208-1DP0x
plus VAT. and shipping
S7-LAN++ connector for Siemens S7 Controller
Smallest S7-PLC-Firewall +++ Controls access to the PPI/MPI/PROFIBUS +++ Of developer and manufacturer
plus VAT. and shipping
S7-LAN connector for Siemens S7 PLC controller
Network-connection for the S7-200/300/400-PLC +++ S7-adapter PPI/MPI/PROFIBUS +++ Of developer and manufacturer +++ Smallest Ethernet-gateway S7 +++ Network for each S7-PLC +++ Fast commissioning +++ Replacement for CP343-1/443-1
plus VAT. and shipping
S7-GATE connector with integrated firewall for Siemens S7-PLCs
Smallest S7-PLC-Firewall +++ Controls access to the PPI/MPI/PROFIBUS +++ Of developer and manufacturer
plus VAT. and shipping
S7-BRIDGE
Online with S7-PLC wo. cables +++ S7-adapter PPI/MPI/PROFIBUS/PN +++ No WIFI-infrastructure +++ Integrated access-point +++ PPI/MPI/DP/PN - LAN - WIFI
plus VAT. and shipping
LAN
smallest simatic S7 ethernet gateway with PD-socket, multifunctional, 1 adapter for all PPI, MPI and Profibus applications
with ext. 24V-connector
easy remote maintenance over internet
S7-cable PPI/MPI/PROFIBUS +++ Ethernet-gateway S7 as cable +++ Network for each S7-PLC +++ Parallel LAN access +++ Ethernet for each S7-PLC
Online with S7-PLC wo. cables +++ S7-adapter Ppi/Mpi/Profibus/Pn +++ No wifi-infrastructure +++ Integrated access-point +++ Ppi/Mpi/Dp/Pn - Lan - Wifi
S7-adapter PPI/MPI/PROFIBUS +++ including PLC-firewall +++ Of developer and manufacturer +++ Smallest Ethernet-gateway S7 +++ Network for each S7-PLC +++ Fast commissioning +++ Replacement for CP343-1/443-1
S7-LAN connector for Siemens S7 PLC controller
Network-connection for the S7-200/300/400-PLC +++ S7-adapter PPI/MPI/PROFIBUS +++ Of developer and manufacturer +++ Smallest Ethernet-gateway S7 +++ Network for each S7-PLC +++ Fast commissioning +++ Replacement for CP343-1/443-1
plus VAT. and shipping
plus VAT. and shipping
S5-LAN++
Industrial Ethernet <> S5 PD-interface (TTY) Including Gateway Plus and S7-TCP / IP functions
plus VAT. and shipping
S7-USB connector for Siemens S7 Controller
universal USB-module on PPI/MPI/Profibus 9,6 KBit/s up to 12MBit/s
plus VAT. and shipping
EtherSens Energy for Rogowski-coils
Energy-analysis (EN 50470-1 EN 50470-3) L1, L2, L3, N realtime analysis Up to 8000 measurements / second Hz / cos phi / power-factor Energy consumption kWh Parallel LAN and WIFI-interface For Rogwski-coils up to 0,5V
plus VAT. and shipping