S5-LAN++
Network-connection for the S5-PLC +++ Network to PG-interface +++ Of developer and manufacturer +++ Remotemaintenance via Internet +++ S5 (CP-343-1 compatible)
Industrial Ethernet <> S5 PD-interface (TTY)
Including Gateway Plus and S7-TCP / IP
functions
Integration of the "old system" into the world of "new and modern systems" using S7-TCPIP with PUT/GET-function.
By plugging the module onto the PG-interface of an S5-PLC, this connection becomes a universally usable connection, a "multi-connection". Multiple and parallel communications at the same time, such as WinCC, PUT/GET from S7-PLC, production-data acquisition, S7-communication-drivers and programming-packages such as Step5 or PG2000.
Advantages:
- Simple and fast networking
- Multiplexer for all protocols
- Integration as S7-300 (CP 343-1)
more...
ARTNR: 9359-LAN
S5-LAN++
EAN number: | 4260363240024 | |
HS-code: | 85423190 | |
Weight: | 0.05 kg |
S5
device type | ||||||
S5-90U |
x
|
+ext. 24V
|
+ext. 24V
|
x
|
x
|
x
|
S5-95U |
x
|
+ext. 24V
|
+ext. 24V
|
x
|
x
|
x
|
S5-100U |
x
|
+ext. 24V(3)
|
+ext. 24V
|
x
|
x
|
x
|
S5-115U |
at 944 + 9359-8
|
at 944 + 9359-8 + ext. 24V (4)
|
x
|
x
|
x
|
x
|
S5-135U |
at 928B + 9359-8
|
at 928B + 9359-8 +ext. 24V (6)
|
x
|
x
|
x
|
x
|
S5-155U |
x
|
x
|
x
|
x
|
x
|
x
|
S5-AG110S |
+9359-5-150 + 9359-4
|
+9359-5-150 + ext. 24V
|
+9359-5-150 + 9359-4(1)
|
|||
S5-AG130W/B |
+9359-5-150 + 9359-4
|
+9359-5-150 + ext. 24V
|
+9359-5-150 + 9359-4(1)
|
|||
S5-AG150A/K/S/U |
+9359-5-150 + 9359-4
|
+9359-5-150 + ext. 24V
|
+9359-5-150 + 9359-4(1)
|
|||
CP-143 |
x
|
x
|
x
|
|||
CP-521 |
+CP521 adapter
|
+CP521 adapter(1)
|
||||
CP-523 |
+CP523 adapter
|
+CP523 adapter(1)
|
||||
CP-525 |
+9359-5(1)
|
|||||
CP-526 |
x
|
x
|
x
|
|||
CP-527 |
x
|
x
|
x
|
|||
CP-528 |
x
|
x
|
x
|
|||
CP-544 |
x (7)
|
x (7)
|
x (7)
|
|||
CP-5430 |
x
|
x
|
x
|
|||
CP-5431 |
x
|
|||||
IP-246 |
x
|
x
|
x
|
|||
IP-247 |
x
|
x
|
x
|
|||
IP-252 |
x
|
x
|
x
|
|||
IP-266 |
x
|
+9359-4(1)
|
||||
WF-470 |
+9359-5-WF470 + 9359-4(1)
|
|||||
SIN-805 |
+9359-6 + ext. 24V(5)
|
+9359-6 + ext. 24V(8)
|
+9359-6(1)
|
|||
SIN-820 |
+9359-6 + ext. 24V(5)
|
+9359-6 + ext. 24V(8)
|
+9359-6(1)
|
|||
SIN-840 |
+9359-6 + ext. 24V(5)
|
+9359-6 + ext. 24V(8)
|
+9359-6(1)
|
|||
SIN-850 |
+9359-6 + ext. 24V(5)
|
+9359-6 + ext. 24V(8)
|
+9359-6(1)
|
|||
SIN-880 |
+9359-6 + ext. 24V(5)
|
+9359-6 + ext. 24V(8)
|
+9359-6(1)
|
|||
Connection on PC |
RS232-port
|
Ethernet RJ45
|
Ethernet RJ45 / WLAN/WIFI
|
USB-port type A
|
RS232-port
|
RS232-port
|
max. prolongation: | 300m (UNI-extension) | 300m (S5-LAN-extension) +ext. 24V | 100m (PG-USB-extension) | 300m (UNI-extension) | ||
(1) ISO adapter can not be used because the required supply voltage on the PG interface of the module is not present. (2) At the CPU 6ES5 102-8MA02 Release 3 is a PG-ISO-Adapter or Netz-Adapter additional required. (3) With S5-LAN++ from HW V2.3 [2010] the "Netz-Adapter" is no more needed, this version has included current-sources. (4) With S5-LAN++ from HW V2.3 [2010] no accessories are needed, this version has included current-sources. (5) With S5-LAN++ from HW V2.3 [2010] the Sinum-Adapter 9359-6-USB is needed. (6) Only for CPU928B with PG-ISO-Adapter and ext. 24V DC, unless there is an S5-LAN++ from HW V2.3 [2010] used. (7) CP544 has bolts at the programming-interface. The products do not fit 100% on this interface. (8) With S5-BRIDGE the Sinum-Adapter 9359-6-USB is needed. |
Remote maintenance
TELE LINK NETWORK
|
||||||||
secured modem-protocol |
✓
|
✓
|
✓
|
|||||
additional software needed |
Siemens TS -Software
|
Siemens TS -Software
|
VPN-Client
|
VPN-Client
|
||||
Providing WinTELEPROF-software |
✓
|
✓
|
✓
|
|||||
modem |
analogue/ISDN
|
analogue
|
opt. via PCMCIA
|
analogue/GSM
|
analogue/ISDN/GSM
|
internet-connection
|
internet-connection
|
internet-connection
|
modem for world wide use |
✓
|
✓
|
✓
|
✓
|
✓
|
|||
interfaces | ||||||||
MPI/Profibus |
9600-12MBd
|
9600-12MBd
|
9600-12MBd
|
9600-12MBd
|
||||
RS232 |
2x
|
2x
|
2x
|
1x
|
1x
|
|||
TTY |
2x
|
2x
|
2x
|
1x
|
||||
PCMCIA |
2x (optionally)
|
1x
|
1x
|
|||||
Ethernet |
10/100BaseTx
|
1x
|
1x
|
5x
|
||||
USB |
2x
|
1x
|
||||||
LCD-display |
✓
|
✓
|
✓
|
✓
|
instead 10 LEDs
|
instead status-LED
|
instead webserver
|
instead webserver
|
supported PLC-protocols * | ||||||||
S7 |
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
||
S5 |
✓
|
✓ (optional)
|
✓ (optional)
|
✓
|
||||
Pilz PSS |
✓
|
✓ (optional)
|
✓ (optional)
|
|||||
Allen-Bradley |
✓
|
✓ (optional)
|
✓ (optional)
|
|||||
AEG |
✓ (optional)
|
✓ (optional)
|
||||||
Bosch |
✓ (optional)
|
✓ (optional)
|
||||||
Telemecanique |
✓ (optional)
|
✓ (optional)
|
||||||
GE-Fanuc |
✓ (optional)
|
✓ (optional)
|
||||||
Klöckner-Moeller |
✓ (optional)
|
✓ (optional)
|
||||||
Mitsubishi |
✓ (optional)
|
✓ (optional)
|
||||||
SMS-sending/Pager(S5/S7) |
✓
|
✓
|
✓
|
✓ (no pager)
|
only for analogue / ISDN
|
|||
HMI-messaging module(S5/S7) |
✓
|
✓
|
||||||
SMS-receive with GSM |
✓
|
|||||||
DTMF with analogue |
✓
|
|||||||
e-mail-dispatch |
✓
|
✓
|
✓
|
|||||
FAX-dispatch(S5/S7) |
✓
|
✓ (optional)
|
✓ (optional)
|
only for analogue / ISDN
|
||||
PLC-data coupling(S5/S7) |
✓
|
✓ (optional)
|
✓ (optional)
|
✓
|
✓
|
|||
ASCII-transfer from S5/S7 |
✓
|
✓ (optional)
|
✓ (optional)
|
only with ASCII-LAN
|
||||
internet-coupling |
✓
|
|||||||
Usage as dial-up-router |
✓
|
✓
|
||||||
power supply |
24V/DC
|
24V/DC
|
24V/DC
|
24V/DC
|
24V/DC
|
24V/DC
|
24V/DC
|
24V/DC
|
dimensions w x h x d (in mm) |
High: 67 x 280 x 170
FLAT: 300 x 175 x 70 |
300 x 175 x 66
|
235 x 162 x 37
|
90 x 162 x 54
|
40 x 125 x 115
|
42 x 15 x 65
|
65 x 43 x 17
|
154 x 92 x 28
|
* other PLC types on request |
Integration of the "old system" into the world of "new and modern systems" using S7-TCPIP with PUT/GET-function.
By plugging the module onto the PG-interface of an S5-PLC, this connection becomes a universally usable connection, a "multi-connection". Multiple and parallel communications at the same time, such as WinCC, PUT/GET from S7-PLC, production-data acquisition, S7-communication-drivers and programming-packages such as Step5 or PG2000.
Advantages:
- Simple and fast networking
- Multiplexer for all protocols
- Integration as S7-300 (CP 343-1)
- Access to S5-data via S7-TCP/IP with PUT/GET
- Qualified support
- Comprehensive documentation
- S5-LAN++ direkt auf PG-Schnittstelle der S5
- S5-LAN++ über Multiplexer PG-MUX-II auf PG-Schnittstelle der S5
- S5-LAN++-Derivat für 3964R über Adapterkabel an CP524/525
- an PC direkt verbunden mit Patch-Kabel
- an PC direkt verbunden mit Cross-Kabel
- an PC über Hub/Switch
- fastest installation to the network of every SIMATIC - S5
- no complicated installation, simply plug on 15pin PD-interface and communicate
- no change in the software in the PLC
- SIMATIC S5 protocols
AS511, RK 512, SINEC-H1 and ISO-on-TCP (RFC 1006) - supported Controls
S5-90U, S5-95U, S5-100U, S5-115U, S5-135U, S5-150U (via intermediate adapter), S5-155U, Sinumerik 810/880 (via intermediate adapter) and COMCON 110 from Berthel - supported data areas
inputs, outputs, flags (also S5 s-flag), datea blocks (also S5 dx-block), timer and counter - easiest configuration with Windows tool (S5 LAN manager)
- at the same time two PG-, four OP/Visualization- and two RFC1006-channel (ISO on TCP)
- speak to S5 as a S7
- integrated multiplexer, parallel use of all protocols
Programming and visualizing simultaneously without any special configuration - external 24V supply optional, otherwise automatically directly from S5-PG socket (from S5-115U)
- supported platforms
S7-TCPIP RFC1006-communication platform independent, otherwise configuration tools/virtual com port for Windows (any) 32/64bit
- Timely communication with the S5-PLC through integrated firmware
- PUT/GET via S7-TCP/IP-access to S5-data (I/O/M/DB/DX/Z/T/S-flags)
- S7-S5-coupling with PUT/GET S7-300/400/1200/1500
- Coupling with WinCC, OPC-server and S7-TCP/IP-software-driver such as IP-S7-LINK (S7 compatible)
- S5 TCP/IP Layer 4
- Access from applications/devices via FETCH/WRITE-protocol to the connected S5-PLC
- S5-LAN-Link (open protocol)
- Compatible with S5-VIPA-TCP/IP
- RFC-1006 connection => pure ISOonTCP (handling blocks scope of delivery)
- RK 512 and TCP/IP H1-ISO-On-TCP RFC1006 (CP1430 TCP) supported
- with WinCC Flexible / TIA (e.g. MP377, TP177B) via S7-TCP/IP to the Simatic S5 (CP-343-1 compatible)
- data exchange between S5 - S5 and S5 - S7 via TCP/IP
- ideal for process visualization
- programming with STEP 5 via Ethernet
- DHCP / Auto-IP supported
- variants: 3964R-LAN, ASCII-LAN, PG-LAN, as RS232-version and for the MUX757
- driver-DLL for Windows available, EXCEL and WORD can read/write S5-data
- including a free Classic OPC-DA-server license "OPC-Manager lite" [limited to 100 items]
- examples and demo-version of communication driver as download available
Applications:
- Connection to SCADA / data-acquisition systems
- Data exchange with S7-PLC (300/400/1200/1500)
- S7-panel as replacement for defective, no more deliverable S5-panel
- remote programming (also via the Internet))
- control central all controls in the plant
Supported S5 protocols / connection-paths:
- AS511 via virtual COM-port PLCVCom
- S7-TCP/IP with PUT/GET-function
- ISO-on-TCP (RFC 1006)
- TCP/IP with H1/ISO-on-TCP
- TCP/IP with RK 512 (3964 and 3864R)
Addressing of the S5-data via S7-TCP-protocol:
The implementation of the data in S5 is largely identical to the S7 and works completely autonomously. F/I/O/T/C are addressed read/write identically.
Even a necessary conversion of the data-types such as S5-float (in KG-format) to S7-float (according to IEEE-754) takes place automatically in both directions.
The address must be converted for DB/DX and S-flags.
For the data blocks, this is usually a factor of 2. You can find examples for DL and DR in the data word in the table:
Simatic S5 | Simatic S7 | Format |
FB11 | FB11 | BYTE |
FW20 | FW20 | WORD |
DB10 DW 9 | DB10.DBW18 | WORD |
DB10 DW60 | DB10.DBW120 | WORD |
DB10 DL3 | DB10.DBB6 | BYTE |
DB10 DR3 | DB10.DBB7 | WORD |
DB10 DD 25 | DB10.DBD50 | DWORD |
DB10 DD 35 | DB10.DBD70 | Real |
Addressing S5 DX-Blocks with S7-TCP/IP
DX Block nr | mapped to S7-DB nr |
DX 1 | DB 257 |
DX 2 | DB 258 |
DX 100 | DB 356 |
Addressiing S5 S-Flag over S7 TCP/IP
Since the S7 does not recognize the S-flags, the S-flags are mapped as data block DB 1000. That means reading and writing on DB 1000 means reading and writing the S-flags
The following applies in the table: x = S-flag number, y = bit number
S-Flag | mapped to S7-DB nr |
S x.y | DB1000.DBX x.y |
SY x | DB1000.DBB x |
SW x | DB1000.DBW x |
SD x | DB1000.DBD x |
S5 goes INDUSTRIE 4.0 (only in german) (Mouse click for enlargement)
Replace defective panels in your "old" S5-systems with current and available S7-panels
To do this, simply insert a placeholder PLC (e.g. 315-2-PN / DP) in the WinCC-project, the IP-address
of the PLC corresponds to the IP-address of the S5-LAN++-module. You can then visualize the data as usual.
At the same time, the PLC can also be programmed/monitored via the network.
Move wirelessly around the S5-PLC and communicate for example ONLINE in the status
Connect each S7-TCP-IP panel to your S5.
Now also available via WLAN for mobile workstations.
PARALLEL several panels and even simultaneous PG connections possible.
Include hard-to-reach places in your ERP system.
With the S5-H1-PG-LAN you would be able to use the H1-path-selection over the S5-LAN++ and communicate with all PLCs in the H1-bus. You don´t have to connect serial to the CP, you can do this easy over your network.
S5-PLC triggered DB-backup/-restore without additional PC via PG-socket and Ethernet on FTP-server
Via digital input triggered DB-backup/-restore without additional PC via PG-socket and Ethernet to FTP-server
S5-PLC triggered DB-backup/-restore without additional PC via PG-socket and Ethernet on SD-card
Via digital input triggered DB-backup/-restore without additional PC via PG-socket and Ethernet to SD-card
S5-PLC triggered DB-backup/-restore without additional PC via PG-socket and Ethernet on USB-stick
Via digital input triggered DB-backup/-restore without additional PC via PG-socket and Ethernet to USB-stick
Coupling S5-controller with PD-port at S5-controller with PD-port via network
Coupling S7-controller with MPI/Profibus at S5-control with PD-port via network
Coupling S7-controller with PN-port at S5-controller with PD-port via network
Remote-maintenance of a Siemens-S5-controller with S5-LAN++ on PD-port via secure VPN-tunnel and scalable firewall
Remote-maintenance of a Siemens-S5-controller with S5-LAN++ on PD-port via secure VPN-tunnel of the TeleRouter
Remote-maintenance of a Siemens-S5-controller with S5-LAN++ on PD-port over separate VPN-server
Supply voltage: | 24V DC +/- 20% |
Power consumption: | 2 watt |
Display: | status-LED |
Handling/Configuration: |
reset-switch-key (factory setting) S5-LAN Manager |
Interfaces: |
to the PLC:
TTY/20mA current loop (S5-LAN activ, S5-PLC passive)
to the PD/PC:
10/100BaseTX RJ45-ethernet jack (auto select) |
Operating system: |
Configuration and operation via virtual COM-interface: MS-Windows XP/2000/7/8/10/11/Server Operation via TCP/IP server: any operating system with a TCP/IP stack |
Operating temperature: | 0 - 55°C |
Case: | ABS-plastic case |
Dimensions: | 42 x 15 x 65 mm |
Scope of delivery: |
S5-LAN++-module Power connector 2pins small |
accessories:
Device upgrade S5-LAN to S5-LAN++
Hardware-update and firmware-upgrade from S5-LAN to S5-LAN++ Including checking the module
plus VAT. and shipping
Read PLC-data from 942F-SPS via S5-LAN++
Project license Communicatio-DLL 32-bit Function/call similar to IPS7-Link-DLL
Read PLC-data from 942F-SPS via S5-LAN++
Project license Communicatio-DLL 64-bit Function/call similar to IPS7-Link-DLL
Read PLC-data from 942F-SPS via S5-LAN++
Project license Communicatio-DLL LINUX 64-bit Function/call similar to IPS7-Link-DLL
Read PLC-data from 942F-SPS via S5-LAN++ branch-lic.
Site / Branch / Standort License Communicatio-DLL 32-bit Function/call similar to IPS7-Link-DLL
Read PLC-data from 942F-SPS via S5-LAN++ branch-lic
Site / Branch / Standort License Communicatio-DLL 64-bit Function/call similar to IPS7-Link-DLL
Read PLC-data from 942F-SPS via S5-LAN++ branch-lic
Site / Branch / Standort License Communicatio-DLL LINUX 64-bit Function/call similar to IPS7-Link-DLL
Read PLC-data from 942F-SPS via S5-LAN++ branch-lic
Site / Branch / Standort License Communicatio-DLL ARM Windows 64-bit Function/call similar to IPS7-Link-DLL
Read PLC-data from 942F-SPS via S5-LAN++ branch-lic
Site / Branch / Standort License Communicatio-DLL ARM LINUX 64-bit Function/call similar to IPS7-Link-DLL
plus VAT. and shipping
Patch-cable 3m, Cat5+, shielded
RJ45 plug <=> RJ45 plug, 1:1
Cross-cable 3m Cat5+, shielded
RJ45 plug <=> RJ45 plug, twisted pinning
USB-powercable for 24V DC, max. 3W
USB-plug type A to 2 open braids 24V DC, maximum current: 125mA (for PC 100mA) length: 5m
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
PG-USB AG-150-adapter
for PG-USB-cable + S5-LAN++ (from HW2.3) to AG-150
AG-150-adapter
for PG-UNI + PG-UNI-II-cable + S5-LAN++ (up to HW2.2) with Netz-Adapter to AG-150
SINUM-adapter
for PG-UNI + PG-UNI-II-cable + S5-LAN++ (up to HW2.2) to SINUMERIK
PG-USB SINUM-adapter
for PG-USB-cable + S5-LAN++ (from HW2.3) to SINUMERIK
plus VAT. and shipping
CP-525-K-adapter
for PG-UNI + PG-UNI-II-cable <-> CP-525- communication
CP-525-K-adapter for PG-USB + S5-LAN++
PG-USB-cable and S5-LAN++ (at east HW V2.3) to CP-525-communication
WF-470-adapter
for PG-UNI + PG-UNI-II-cable <-> WF470
PG-USB WF-470-adapter
for PG-USB-cable <-> WF470
plus VAT. and shipping
S5-LAN++
Industrial Ethernet <> S5 PD-interface (TTY) Including Gateway Plus and S7-TCP / IP functions
plus VAT. and shipping
S5-BRIDGE
ONLINE with S5PLC without cable +++ S5-adapter 90-155U/CPs/IPs +++ No WIFi-infrastructure +++ Integrated access-point +++ Configuration via WebAccess +++ S5 Bridge (TTY - LAN - WIFI)
plus VAT. and shipping
plus VAT. and shipping
S5-LAN++ RS232-version
Industrial Ethernet <=> S5 PD-interface (RS232), inclusive adapter cable (15pin female <=> 9pin male)
plus VAT. and shipping
S5-3964R-LAN RS232-version
Communication with 3964/9364R-client with S7-TCPIP inclusive adapter cable (15pin female <=> 9pin male)
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
Internet
The simple and quick router solution for automation
Turbo ethernet for PLC-oldie Simatic S5
S5 over LAN
Simatic S5 ethernet gateway with Wifi for TTY
Remotesupport without configuration / Machine access without IT
Internet-coupling/communication
Remotesupport without configuration / Machine access without IT
smallest simatic S7 ethernet gateway with PD-socket, multifunctional, 1 adapter for all PPI, MPI and Profibus applications
with ext. 24V-connector
easy remote maintenance over internet
Industrial WLAN-Router +++ High-speed datarate 150 Mbit/s +++ Integrated firewall +++ Din-rail-mounting +++ Make your own WIFI
The simple and quick router solution for automation
S7-LAN connector for Siemens S7 PLC controller
Network-connection for the S7-200/300/400-PLC +++ S7-adapter PPI/MPI/PROFIBUS +++ Of developer and manufacturer +++ Smallest Ethernet-gateway S7 +++ Network for each S7-PLC +++ Fast commissioning +++ Replacement for CP343-1/443-1
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
Automatic-mode
Main downloads
Versionstory
- Release-docu 3964R-LAN-firmware
- Release-docu ASCII-LAN-firmware
- Release-docu Multi-VCom
- Release-docu PLCVCom
- Release-docu S5-H1-PG-LAN-firmware
- Release-docu S5-LAN++-firmware
- Release-docu S5-LAN-Manager
- Release-docu S5-LAN-PATH-firmware
- Release-docu S5-Patch
- Release-docu S5-PG-LAN-firmware
- Release-docu S5-VCom