TELE-PROFessional-II (TP-II)















Programming of S5- and S7-PLC’s via telephone from afar
OEM - Version (all accessories optional)
without PCMCIA-Slot for UMTS-/LAN-card
- Secured modem-protocol, no additional software needed
- UMTS- / VPN- / internet-service
- Also for PLC’s with ProfiNet
- SMS and fax sending directly from S7-300/400 (no PLC-programming necessary)
- Analogue modem couples automatically via ISDN
more...
variants:
ARTNR: 9372-OEM
TELE-PROFessional II worldwide use
1260,00 € plus VAT. and shipping
ARTNR: 9372-OEM
TELE-PROFessional II worldwide use
EAN number: | 4260363240062 | |
HS-code: | 85389099 | |
Weight: | 2.05 kg |
Remote maintenance
![]() |
||||||||
secured modem-protocol |
✓
|
✓
|
✓
|
|||||
additional software needed |
Siemens TS -Software
|
Siemens TS -Software
|
VPN-Client
|
VPN-Client
|
||||
Providing WinTELEPROF-software |
✓
|
✓
|
✓
|
|||||
modem |
analogue/ISDN
|
analogue
|
opt. via PCMCIA
|
analogue/GSM
|
analogue/ISDN/GSM
|
internet-connection
|
internet-connection
|
internet-connection
|
modem for world wide use |
✓
|
✓
|
✓
|
✓
|
✓
|
|||
interfaces | ||||||||
MPI/Profibus |
9600-12MBd
|
9600-12MBd
|
9600-12MBd
|
9600-12MBd
|
||||
RS232 |
2x
|
2x
|
2x
|
1x
|
1x
|
|||
TTY |
2x
|
2x
|
2x
|
1x
|
||||
PCMCIA |
2x (optionally)
|
1x
|
1x
|
|||||
Ethernet |
10/100BaseTx
|
1x
|
1x
|
5x
|
||||
USB |
2x
|
1x
|
||||||
LCD-display |
✓
|
✓
|
✓
|
✓
|
instead 10 LEDs
|
instead status-LED
|
instead webserver
|
instead webserver
|
supported PLC-protocols * | ||||||||
S7 |
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
||
S5 |
✓
|
✓ (optional)
|
✓ (optional)
|
✓
|
||||
Pilz PSS |
✓
|
✓ (optional)
|
✓ (optional)
|
|||||
Allen-Bradley |
✓
|
✓ (optional)
|
✓ (optional)
|
|||||
AEG |
✓ (optional)
|
✓ (optional)
|
||||||
Bosch |
✓ (optional)
|
✓ (optional)
|
||||||
Telemecanique |
✓ (optional)
|
✓ (optional)
|
||||||
GE-Fanuc |
✓ (optional)
|
✓ (optional)
|
||||||
Klöckner-Moeller |
✓ (optional)
|
✓ (optional)
|
||||||
Mitsubishi |
✓ (optional)
|
✓ (optional)
|
||||||
SMS-sending/Pager(S5/S7) |
✓
|
✓
|
✓
|
✓ (no pager)
|
only for analogue / ISDN
|
|||
HMI-messaging module(S5/S7) |
✓
|
✓
|
||||||
SMS-receive with GSM |
✓
|
|||||||
DTMF with analogue |
✓
|
|||||||
e-mail-dispatch |
✓
|
✓
|
✓
|
|||||
FAX-dispatch(S5/S7) |
✓
|
✓ (optional)
|
✓ (optional)
|
only for analogue / ISDN
|
||||
PLC-data coupling(S5/S7) |
✓
|
✓ (optional)
|
✓ (optional)
|
✓
|
✓
|
|||
ASCII-transfer from S5/S7 |
✓
|
✓ (optional)
|
✓ (optional)
|
only with ASCII-LAN
|
||||
internet-coupling |
✓
|
|||||||
Usage as dial-up-router |
✓
|
✓
|
||||||
power supply |
24V/DC
|
24V/DC
|
24V/DC
|
24V/DC
|
24V/DC
|
24V/DC
|
24V/DC
|
24V/DC
|
dimensions w x h x d (in mm) |
High: 67 x 280 x 170
FLAT: 300 x 175 x 70 |
300 x 175 x 66
|
235 x 162 x 37
|
90 x 162 x 54
|
40 x 125 x 115
|
42 x 15 x 65
|
65 x 43 x 17
|
154 x 92 x 28
|
* other PLC types on request |
- Secured modem-protocol, no additional software needed
- UMTS- / VPN- / internet-service
- Also for PLC’s with ProfiNet
- SMS and fax sending directly from S7-300/400 (no PLC-programming necessary)
- Analogue modem couples automatically via ISDN
- With integrated CP-343-1 / 443-1 functionality
- Ethernet also for router function
- PCMCIA-slots (only for version -H) for extensions (memory cards / specific modem cards (GSM) / WLAN)
- Compatible to the forerunner model (TELE-Prof / TELE-Book / TELE-Link)
- Also as TCP/IP-router
- S7-variables display via Web-Browser
- S7-remote maintenance with MPI-Interface
- S5-remote maintenance (access to every S5 direct / via H1, L1, L2 and KOR/MUX)
- Integrated telephone directory
- Call-back of partner possible
- Software-update via PC (LAN) respectively from device to device possible
Remote maintenance / telecontrol of PLC

Access to the connected PLC takes place by coupling via Analogue-, ISDN-, mixed Analogue-ISDN-, GSM-, UMTS-line and also via Internet with and without VPN-security.
Analogue and ISDN - how do they come together?

You have on the plant side only ISDN for telephone, but in your office there is only an analogue system? No problem, you have to install on the clients side the TP-II and activate there the analogue-emulation in the device. No, the modem signals will be send digitalized over ISDN and you can connect to it. So, you will be able to communicate though the telephone systems are different and your client isn´t forced to install an analogue connection.
Router - Mode (access to the network without router)

The Tele-Prof-II can also be used as a router for access from a PC via dial-up connection, so that a communication with the behind covered network results. Furthermore a network connection can be
made with the TP-II <=> TP-II-line, but in doing so the IP-address-root must differ.
User dependant network access

You have PLC/LAN-participants different supplier in your network and everybody should have access to this network? No problem, you give every supplier a VPN-username and passwort, define in the
destination device a user-dependent network-access and after positiv login he only can communicate to the released ip-addresses.
Separate your machine-net from the office-net

You need a separation between the machine-net and the office-net? No problem, plug a PCMCIA-LAN-card in your Tele-Prof-II-device (only for version -H) and the separation is OK. You have access to
both nets via remote maintenance.
S7-CP-alternate (without LAN-CP to the PLC)

Do you have a PLC without CP343-1 or CP443-1 and a TP-II as remote maintenance device? Then activate the CP-mode of the TP-II and your visualisation goes directly ONLINE via the LAN of the TP-II.
PLC coupling (data exchange between PLCs)

Your pumping stations report the water levels of the central control via telephone network. The central office itself can of course transmit commands/messages to the substations as well. Thereto no
dedicated line is required, a “normal” telephone connection is sufficient because the devices cut the line after occured message.
Failure report transmission without any change in the PLC programm

Your outstation reports the current value cyclically, or in case of malfunction the status via FAX, as SMS to your mobile phone, to your pager or also via e-mail. And this without an intervention
of the PLC-program. Here the variables and actions are stored and processed in the TP-II.
Failure report transmission released by the PLC

Your outstation reports the current value cyclically, or in case of malfunction the status via FAX, as SMS to your mobile phone, to your pager or also via e-mail.
Remote maintenance of centralized PLC-devices

You have many PLC and you want to programm them central on one place? No problem, you have to connect them all to the KOR/MUX-Tele-Switch, connect it with the TP-II and after telephone connect you
will be able with the PD-bus-selection of your Step5-software to go ONLINE. Of course the MOR/MUX-Tele-Switch is cascadable, so you can connect up to 30 PLCs to the devices.
Sending ASCII-data to a PC

Your car park or control sends the configuration / capacity utilisation to a PC with a modem, so that the data can be used for further processing.
Direct-mode "extended serial interface"

There is an unsupported control or data logger or converter integrated in your installation which protocol is not supported? No problem, the signs that the PC in the office sends will be
transferred via telephone line by the Direct-mode, and on-site reproduced by the TP-II. The way back is identical. So in that case there’s also a communication to the electronic devices
available.
Data logger with FTP-interface

You need a data logger which tape-records the specified data of the PLC and you can collect the data via FTP on demand. No problem, TP-II with the option Datalogger is the solution for you.
Supply voltage: | 24V DC +/- 20% |
Power consumption: | 15 watt |
Display: |
expressive LCD display 5 status LEDs |
Handling/Configuration: |
integrated keypad WEB-Browser |
Interfaces: |
to the PLC:
PPI/MPI/Profibus interface: 9,6 KBd - 12 MBdTTY/20mA current loop (AG-TELE aktiv, PLC passiv) RS232: 9,6 KBd - 115,2 KBd / fully assigned
to the PD/PC:
10/100BaseTX RJ45-ethernet jackTTY/20mA current loop (100 % mechanically and electr. compatible) RS232: 9,6 KBd - 115,2 KBd / with a 1on1-cable to the PC
others:
2xUSB, 2xPCMCIA (only for version -H) |
Integrated modem: |
33K6 HIGH-SPEED, V.42/BIS MNP5 analogue modem ISDN (Euro ISDN + 1TR6) |
Operating temperature: | 0 - 55°C |
Case: | powder coated metal case with mounting flange and DIN-rail mounting |
Dimensions: |
Flat 300 x 175 x 70 mm Hoch 67 x 280 x 170 mm |
Scope of delivery: | |
Tele-Prof-II Power connector 3pins big |
All prices plus costs of delivery, shipping insurance and VAT.
accessories:
11,00 €
plus VAT. and shipping
plus VAT. and shipping
28,00 €
plus VAT. and shipping
plus VAT. and shipping
81,00 €
plus VAT. and shipping
plus VAT. and shipping
87,00 €
plus VAT. and shipping
plus VAT. and shipping
90,00 €
plus VAT. and shipping
plus VAT. and shipping
102,00 €
plus VAT. and shipping
plus VAT. and shipping
25,00 €
plus VAT. and shipping
plus VAT. and shipping
25,00 €
plus VAT. and shipping
plus VAT. and shipping
25,00 €
plus VAT. and shipping
plus VAT. and shipping
11,00 €
plus VAT. and shipping
plus VAT. and shipping
25,00 €
plus VAT. and shipping
plus VAT. and shipping
25,00 €
plus VAT. and shipping
plus VAT. and shipping
25,00 €
plus VAT. and shipping
plus VAT. and shipping
11,00 €
plus VAT. and shipping
plus VAT. and shipping
25,00 €
plus VAT. and shipping
plus VAT. and shipping
244,00 €
plus VAT. and shipping
plus VAT. and shipping
22,00 €
plus VAT. and shipping
plus VAT. and shipping
63,00 €
plus VAT. and shipping
plus VAT. and shipping
172,00 €
plus VAT. and shipping
plus VAT. and shipping
4,00 €
plus VAT. and shipping
plus VAT. and shipping
105,00 €
plus VAT. and shipping
plus VAT. and shipping
199,00 €
plus VAT. and shipping
plus VAT. and shipping
11,00 €
plus VAT. and shipping
plus VAT. and shipping
27,00 €
plus VAT. and shipping
plus VAT. and shipping
42,00 €
plus VAT. and shipping
plus VAT. and shipping
11,00 €
plus VAT. and shipping
plus VAT. and shipping
11,00 €
plus VAT. and shipping
plus VAT. and shipping
All prices plus costs of delivery, shipping insurance and VAT.
Variationen:
9372-FLAT
TELE-PROFessional II worldwide use
flat version / OEM - Version (all accessories optional) without PCMCIA-slot for UMTS-/LAN-card
TELE-PROFessional II worldwide use
flat version / OEM - Version (all accessories optional) without PCMCIA-slot for UMTS-/LAN-card

1260,00 €
plus VAT. and shipping
plus VAT. and shipping
9372-FLAT-H
TELE-PROFessional II worldwide use
flat version / OEM - Version (all accessories optional) with PCMCIA-slot for UMTS-/LAN-Card
TELE-PROFessional II worldwide use
flat version / OEM - Version (all accessories optional) with PCMCIA-slot for UMTS-/LAN-Card
1313,00 €
plus VAT. and shipping
plus VAT. and shipping
Analogue-telefone

Facilities management world wide – remote maintenance and diagnosis via telephone

PLC-remote maintenance also available from the car, with 12V power supply

configuration / update of TELE-Network devices from PC (Windows-Software)

replacement of the PD-TELE at telephone bounded remote maintenance

The simple and quick router solution for automation
Analogue-telefone

Facilities management world wide – remote maintenance and diagnosis via telephone

PLC-remote maintenance also available from the car, with 12V power supply

configuration / update of TELE-Network devices from PC (Windows-Software)

replacement of the PD-TELE at telephone bounded remote maintenance

Programming of S7-PLC’s via telephone from afar

The simple and quick router solution for automation
ISDN

replacement of the PD-TELE at telephone bounded remote maintenance

The simple and quick router solution for automation
ISDN

replacement of the PD-TELE at telephone bounded remote maintenance

The simple and quick router solution for automation

Remote maintenance of PPI, MPI and Profibus <=> analogue 56K-, ISDN-, GSM-Modem

Remote maintenance of PPI, MPI and Profibus <=> analogue 56K-, ISDN-, GSM-Modem
All prices plus costs of delivery, shipping insurance and VAT.
11,00 €
plus VAT. and shipping
plus VAT. and shipping
9352-LANCON
S7-LAN connector for Siemens S7 PLC controller
S7-adapter PPI/MPI/PROFIBUS +++ Of developer and manufacturer +++ Smallest Ethernet-gateway S7 +++ Network for each S7-PLC +++ Fast commissioning +++ Replacement for CP343-1/443-1
S7-LAN connector for Siemens S7 PLC controller
S7-adapter PPI/MPI/PROFIBUS +++ Of developer and manufacturer +++ Smallest Ethernet-gateway S7 +++ Network for each S7-PLC +++ Fast commissioning +++ Replacement for CP343-1/443-1

423,00 €
plus VAT. and shipping
plus VAT. and shipping
9359-LAN
S5-LAN++
Industrial Ethernet <> S5 PD-interface (TTY) Including Gateway Plus and S7-TCP / IP functions
S5-LAN++
Industrial Ethernet <> S5 PD-interface (TTY) Including Gateway Plus and S7-TCP / IP functions

452,00 €
plus VAT. and shipping
plus VAT. and shipping
11,00 €
plus VAT. and shipping
plus VAT. and shipping
174,00 €
plus VAT. and shipping
plus VAT. and shipping
145,00 €
plus VAT. and shipping
plus VAT. and shipping