Cookies helfen uns bei der Bereitstellung unserer Dienste. Durch die Nutzung unserer Dienste erklären Sie sich damit einverstanden, dass wir Cookies setzen.
Cookies help us in providing our services. By using our services, you agree that we set cookies.
OK
K-9359-LAN - Process Informatik Entwicklungsgesellschaft mbH

K-9359-LAN


KTP-panel to S5-PLC

Industrial Ethernet <=> S5 PD-interface (TTY)

The upgrade for every SIMATIC S5-PLC without changes to the hardware- and software-configuration to S7-300 with CP343-1.
Integration of the "old system" into the world of "new and modern systems" using S7-TCPIP with PUT/GET-function.
By plugging the module onto the PG-interface of an S5-PLC, this connection becomes a universally usable connection, a "multi-connection". Multiple and parallel communications at the same time, such as WinCC, PUT/GET from S7-PLC, production-data acquisition, S7-communication-drivers and programming-packages such as Step5 or PG2000.

Advantages:
  • Simple and fast networking
  • Multiplexer for all protocols
  • Integration as S7-300 (CP 343-1)

more...
452,00 € plus VAT. and shipping

ARTNR: K-9359-LAN
Kleverles project KTP-Panell with S5-PLC
EAN number: 4260363240024
HS-code: 85423190



The upgrade for every SIMATIC S5-PLC without changes to the hardware- and software-configuration to S7-300 with CP343-1.
Integration of the "old system" into the world of "new and modern systems" using S7-TCPIP with PUT/GET-function.
By plugging the module onto the PG-interface of an S5-PLC, this connection becomes a universally usable connection, a "multi-connection". Multiple and parallel communications at the same time, such as WinCC, PUT/GET from S7-PLC, production-data acquisition, S7-communication-drivers and programming-packages such as Step5 or PG2000.

Advantages:
  • Simple and fast networking
  • Multiplexer for all protocols
  • Integration as S7-300 (CP 343-1)
  • Access to S5-data via S7-TCP/IP with PUT/GET
  • Qualified support
  • Comprehensive documentation
Anschlussmöglichkeiten:
  • S5-LAN++ direkt auf PG-Schnittstelle der S5
  • S5-LAN++ über Multiplexer PG-MUX-II auf PG-Schnittstelle der S5
  • S5-LAN++-Derivat für 3964R über Adapterkabel an CP524/525
  • an PC direkt verbunden mit Patch-Kabel
  • an PC direkt verbunden mit Cross-Kabel
  • an PC über Hub/Switch
Features:
  • fastest installation to the network of every SIMATIC - S5
  • no complicated installation, simply plug on 15pin PD-interface and communicate
  • no change in the software in the PLC
  • SIMATIC S5 protocols
    AS511, RK 512, SINEC-H1 and ISO-on-TCP (RFC 1006)
  • supported Controls
    S5-90U, S5-95U, S5-100U, S5-115U, S5-135U, S5-150U (via intermediate adapter), S5-155U, Sinumerik 810/880 (via intermediate adapter) and COMCON 110 from Berthel
  • supported data areas
    inputs, outputs, flags (also S5 s-flag), datea blocks (also S5 dx-block), timer and counter
  • easiest configuration with Windows tool (S5 LAN manager)
  • at the same time two PG-, four OP/Visualization- and two RFC1006-channel (ISO on TCP)
  • speak to S5 as a S7
  • integrated multiplexer, parallel use of all protocols
    Programming and visualizing simultaneously without any special configuration
  • external 24V supply optional, otherwise automatically directly from S5-PG socket (from S5-115U)
  • supported platforms
    S7-TCPIP RFC1006-communication platform independent, otherwise configuration tools/virtual com port for Windows (any) 32/64bit
  • Timely communication with the S5-PLC through integrated firmware
  • PUT/GET via S7-TCP/IP-access to S5-data (I/O/M/DB/DX/Z/T/S-flags)
  • S7-S5-coupling with PUT/GET S7-300/400/1200/1500
  • Coupling with WinCC, OPC-server and S7-TCP/IP-software-driver such as IP-S7-LINK (S7 compatible)
  • S5 TCP/IP Layer 4
  • Access from applications/devices via FETCH/WRITE-protocol to the connected S5-PLC
  • S5-LAN-Link (open protocol)
  • Compatible with S5-VIPA-TCP/IP
  • RFC-1006 connection => pure ISOonTCP (handling blocks scope of delivery)
  • RK 512 and TCP/IP H1-ISO-On-TCP RFC1006 (CP1430 TCP) supported
  • with WinCC Flexible / TIA (e.g. MP377, TP177B) via S7-TCP/IP to the Simatic S5 (CP-343-1 compatible)
  • data exchange between S5 - S5 and S5 - S7 via TCP/IP
  • ideal for process visualization
  • programming with STEP 5 via Ethernet
  • DHCP / Auto-IP supported
  • variants: 3964R-LAN, ASCII-LAN, PG-LAN, as RS232-version and for the MUX757
  • driver-DLL for Windows available, EXCEL and WORD can read/write S5-data
  • including a free Classic OPC-DA-server license "OPC-Manager lite" [limited to 100 items]
  • examples and demo-version of communication driver as download available

Applications:

  • Connection to SCADA / data-acquisition systems
  • Data exchange with S7-PLC (300/400/1200/1500)
  • S7-panel as replacement for defective, no more deliverable S5-panel
  • remote programming (also via the Internet))
  • control central all controls in the plant

Supported S5 protocols / connection-paths:

  • AS511 via virtual COM-port PLCVCom
  • S7-TCP/IP with PUT/GET-function
  • ISO-on-TCP (RFC 1006)
  • TCP/IP with H1/ISO-on-TCP
  • TCP/IP with RK 512 (3964 and 3864R)

Addressing of the S5-data via S7-TCP-protocol:
The implementation of the data in S5 is largely identical to the S7 and works completely autonomously. F/I/O/T/C are addressed read/write identically. Even a necessary conversion of the data-types such as S5-float (in KG-format) to S7-float (according to IEEE-754) takes place automatically in both directions. The address must be converted for DB/DX and S-flags.
For the data blocks, this is usually a factor of 2. You can find examples for DL and DR in the data word in the table:

Simatic S5Simatic S7Format
FB11FB11BYTE
FW20FW20WORD
DB10 DW 9DB10.DBW18WORD
DB10 DW60DB10.DBW120WORD
DB10 DL3DB10.DBB6BYTE
DB10 DR3DB10.DBB7WORD
DB10 DD 25DB10.DBD50DWORD
DB10 DD 35DB10.DBD70Real

Addressing S5 DX-Blocks with S7-TCP/IP
DX Block nrmapped to S7-DB nr
DX 1DB 257
DX 2DB 258
DX 100DB 356

Addressiing S5 S-Flag over S7 TCP/IP
Since the S7 does not recognize the S-flags, the S-flags are mapped as data block DB 1000. That means reading and writing on DB 1000 means reading and writing the S-flags
The following applies in the table: x = S-flag number, y = bit number
S-Flagmapped to S7-DB nr
S x.yDB1000.DBX x.y
SY xDB1000.DBB x
SW xDB1000.DBW x
SD xDB1000.DBD x

S5 goes INDUSTRIE 4.0 (only in german) (Mouse click for enlargement)



Supply voltage: 24V DC +/- 20%
Power consumption: 2 watt
Display: status-LED
Handling/Configuration: reset-switch-key (factory setting)
S5-LAN Manager
Interfaces:
to the PLC:
TTY/20mA current loop (S5-LAN activ, S5-PLC passive)
to the PD/PC:
10/100BaseTX RJ45-ethernet jack (auto select)
Operating system: Configuration and operation via virtual COM-interface: MS-Windows XP/2000/7/8/10/11/Server
Operation via TCP/IP server: any operating system with a TCP/IP stack
Operating temperature: 0 - 55°C
Case: ABS-plastic case
Dimensions: 42 x 15 x 65 mm
 
Scope of delivery: S5-LAN++-module
Power connector 2pins small
All prices plus costs of delivery, shipping insurance and VAT.
All prices plus costs of delivery, shipping insurance and VAT.
All prices plus costs of delivery, shipping insurance and VAT.

9359-LAN
S5-LAN++

Industrial Ethernet <> S5 PD-interface (TTY) Including Gateway Plus and S7-TCP / IP functions
Quickbestellung INFOMAIL
by e-mail
452,00 €
plus VAT. and shipping