EtherSens Control 24V Analog-IO V1.1
Capture analogue IO +++ Monitor analogue IO +++ PLC-fault messaging +++ PLC-data logging/saving +++ Convert control tasks
Supply voltage: 24V DC
4 x Analogue Input (switchable between U, I,
differential)
4 x analog OUT 0/4-20mA (24V)
LAN and WIFI-interface integrated
function to the same time
Features:
- Sends alarm-messages controlled by the PLC
- Receiver in the PLC deposited, so ONLINE replaceable
- Messages in the PLC deposited, so ONLINE replaceable
more...
ARTNR: 9200-A-24V-V1.1
EtherSens Control 24V Analog-IO V1.1
EAN number: | 4260363246972 | |
HS-code: | 85423190 | |
Weight: | 0.2 kg |
Features:
- Sends alarm-messages controlled by the PLC
- Receiver in the PLC deposited, so ONLINE replaceable
- Messages in the PLC deposited, so ONLINE replaceable
- Communication with a controller via optional IO-modules, LTE or via network S7-TCPIP RFC1006
- S7-PLC over S7-LAN-module
- S5-PLC over S5-LAN++-module
- Solve control-tasks via integrated logic-module
- Implementation of different protocols, for e.g. L1-bus-communication via RFC1006, Modbus
- Coupling of multiple devices to a network
- Coupling with WinCC and access to process values
Application-examples (only german language):
S5-PLC triggered DB-backup/-restore without additional PC via PG-socket and Ethernet on FTP-server
Via digital input triggered DB-backup/-restore without additional PC via PG-socket and Ethernet to FTP-server
S5-PLC triggered DB-backup/-restore without additional PC via PG-socket and Ethernet on SD-card
Via digital input triggered DB-backup/-restore without additional PC via PG-socket and Ethernet to SD-card
S5-PLC triggered DB-backup/-restore without additional PC via PG-socket and Ethernet on USB-stick
Via digital input triggered DB-backup/-restore without additional PC via PG-socket and Ethernet to USB-stick
S7-PLC triggered DB-backup/-restore without additional PC via PN-port on FTP-server
Via digital input triggered DB-backup/-restore without additional PC via PN-port to FTP-server
S7-PLC triggered DB-backup/-restore without additional PC via PN-port on SD card
Via digital input triggered DB-backup/-restore without additional PC via PN-port to SD-card
S7-PLC triggered DB-backup/-restore without additional PC via PN-port to USB-stick
Via digital input triggered DB-backup/-restore without additional PC via PN-port to USB-stick
S7-PLC triggered DB-backup/-restore without additional PC via MPI/Profibus on FTP-server
Via digital input triggered DB-backup/-restore without additional PC via MPI/Profibus to FTP-server
S7-PLC triggered DB-backup/-restore without additional PC via MPI/Profibus on SD-card
Via digital input triggered DB-backup/-restore without additional PC via MPI/Profibus to SD-card
S7-PLC triggered DB-backup/-restore without additional PC via MPI/Profibus on USB-stick
Via digital input triggered DB-backup/-restore without additional PC via MPI/Profibus to USB-stick
By connecting a line-recorder to the EtherSens-device anyone without network-knowledge can visually capture and further process the log.
Apply small control tasks of your systems with EtherSens-Control-devices. Determine switching points where the device is running to respond. Depending on the parameterization, an email or SMS notification (depending on the device-configuration) or the device automatically controls via the optional IO-modules (analog / digital / relay).
Supply voltage: | 24V DC +/- 20% |
Power consumption: | 6 watt (without possibly switched outputs) |
Display: |
WEB-Browser 1 status LED bicolor |
Handling/Configuration: | WEB-Browser |
Interfaces: |
4 x Analogue Input V1.1 (switchable between U, I, differential) - Free configurable voltage-inputs with full 15-bit resolution: 0-50V, 0-40V, 0-20V, 0-10V, 0-5V, 0-4V, 0-2V, 0-1V, 0-0,5V, 0-0,25V - Free configurable differential voltage-inputs with full 15-bit resolution AI1 <-> AI2 and AI3 <-> AI4: +/-50V, +/-40V, +/-10V, +/-5V, +/-4V, +/-2V, +/-1V, +/-0,5V, +/-0,25V - Free configurable current-inputs with full 15-bit resolution: 0-20mA, 4-20mA - sample-rate of AD-converter can be selected: - fast = fast conversion / short precision - balanced = middle conversion / middle precision - exact = slow conversion / high precision - Measuring ranges after changing are calibrated to: - offset for 0V / 0mA - slope of voltage / current (ideal for end of measuring-range / full-scale) - Relative values can be configured to the original voltage- / current-values. For e.g.: On the voltage-input 10V were measured 5V, relative minimum = 0 kg, relative maximum = 100 kg, so the displayed-value is 50 kg Is minimum and maximum configured as 0 the measured voltage- / current-value will be displayed. 4 x analogue Output 0/4-20mA (source-power 24V) Slot for microSD Antenna-connector SMA(f) (2.4 GHz IEEE 802.11b/g) 10/100BaseTX RJ45-ethernet-plug Button for factory settings |
Overvoltage category: | CAT IV |
Insulation value network <=> mains voltage: |
1,5 KV |
Operating temperature: | 0 - 55°C |
Case: | ABS-plastic case V0 |
Dimensions: | 100 x 112 x 45 mm |
Scope of delivery: |
EtherSens Control WIFI-stub-antenna |
accessories:
plus VAT. and shipping
plus VAT. and shipping
Stationary Wifi-antenna for wall fastening
for EtherSens-devices, cable length: 5m for indoor and outdoor use incl. bracket
plus VAT. and shipping
Option Safe S7-PLC-data-transmission
Function extension for recognition of save data-transmission by toggle bit or counters in the S7-PLC. In case of a failure, a default configuration is mapped to the outputs.
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
Patch-cable 0.25m, Cat5e, shielded
RJ45 plug <=> RJ45 plug, 1:1
Cross-cable 3m Cat5+, shielded
RJ45 plug <=> RJ45 plug, twisted pinning
Patch-cable 3m, Cat5+, shielded
RJ45 plug <=> RJ45 plug, 1:1
extensions:
Extension Analog-IO V1.0
Extension-board for EtherSens-devices 4 x analog IN 0-5V opt. with ext.Shunt 0/4-20mA opt. with ext. restistance 0-10/24/50V 4 x analog OUT 0/4-20mA (24V) Power consumption: 4W
plus VAT. and shipping
Extension with ext. galv. separated I2C 5V
Extension-board for EtherSens-devices with galvanic separated external I2C-connector for 5V Power consumption: 2W
plus VAT. and shipping
Extension LTE-modem
LTE-modem-board for EtherSens-devices Send/receive of SMS-messages Communication from/into internet Power consumption: 6,5W
plus VAT. and shipping
Extension Energy-IO
Extension-board for EtherSens-devices Energy-analysis (EN 50470-1 EN 50470-3) L1, L2, L3, N realtime analysis Up to 8000 measurements / second Hz / cos phi / power-factor Energy consumption kWh For Rogwski-coils up to 0,5V
plus VAT. and shipping
U-I-box for EtherSens
max. 1000V DC / 40A 24V DC supply 20cm power-cable 4mm2 with Amphenol-plug I2C-connection 1m
plus VAT. and shipping
Sun-light-sensor for EtherSens
max. 220k Lux (switchable ranges) 3.3V DC supply (from I2C-interfaceport) I2C-connection 1m
plus VAT. and shipping
Gyro-Sensor 312 for EtherSens
Measuring range: ±1.5g / ±3g / ±6g / ±12g 3.3V DC supply (from I2C-interfaceport) I2C-connection 1m
plus VAT. and shipping
Gyro-Sensor 313 for EtherSens
Measuring range: ±0.5g / ±1g / ±2g / ±4g 3.3V DC supply (from I2C-interfaceport) I2C-connection 1m
plus VAT. and shipping
Temp./humidity/air-pressure for EtherSens
Measuring range: Temperature: -40 ...+85°C Humidity: 0...100% relative Feuchte Pressure: 300...1100 hPa 3.3V DC supply (from I2C-interfaceport) I2C-connection 1m
plus VAT. and shipping
Segment-display for EtherSens
4 Digit 14 segment-display WHITE 0,56" high in wall-mounting case 5V DC supply (from I2C-interfaceport) I2C-connection
plus VAT. and shipping
Extension with ext. galv. separated I2C 3.3V
Extension-board for EtherSens-devices with galvanic separated external I2C-connector for 3.3V Power consumption: 2W
plus VAT. and shipping
Extension RS485-IO
Extensionboard for EtherSens-devices V1.0 for RS485 Power consumption: 2W
plus VAT. and shipping
Extension TTY-IO
Extensionboard for EtherSens-devices V1.0 for TTY (incl. 2x current-sources) Power consumption: 2W
plus VAT. and shipping
Extension Digital-IO
Extension-board for EtherSens-devices 12 x digital IN or OUT 24VDC 400mA free config with software Power consumption: 4W
plus VAT. and shipping
Extension 24V Relay-IO
Extension-board for EtherSens-devices Supply voltage: 24V DC 4 x relay-OUT 230VAC/16A Power consumption: 4W
plus VAT. and shipping
Extension 230V Relay-IO
Extension-board for EtherSens-devices Supply voltage: 230V AC 4 x relay-OUT 230VAC/16A Power consumption: 2,5W
plus VAT. and shipping
Power-supply-rack-unit 230V
Input voltage: 100 - 240VAC 50-60Hz Output voltage: 24V DC Power: 4W
plus VAT. and shipping
Extension Analog-IO V1.1
Extension-board for EtherSens-devices 4 x Analogue Input (switchable between U, I, differential) 4 x analog OUT 0/4-20mA (24V) Power consumption: 4W
plus VAT. and shipping
Extension RS422-IO
Extensionboard for EtherSens-devices V1.0 for RS422 (4-wire) Power consumption: 2W
plus VAT. and shipping
Extension RS232-IO
Extensionboard for EtherSens-devices V1.0 for RS232 (RxD, TxD) Power consumption: 2W
plus VAT. and shipping
Extension USB-port
USB-port for EtherSens-devices (data storage) Extension for: - DB-backup/restoure-function - CSV-recording Maximum current: 200mA for 5V DC
plus VAT. and shipping
EtherSens Control 24V Analog-IO V1.1
Supply voltage: 24V DC 4 x Analogue Input (switchable between U, I, differential) 4 x analog OUT 0/4-20mA (24V) LAN and WIFI-interface integrated function to the same time
plus VAT. and shipping
EtherSens Control 24V Analog-IO V1.0
Supply voltage: 24V DC 4 x analog IN 0-5V opt. with ext.Shunt 0/4-20mA opt. with ext. restistance 0-10/24/50V 4 x analog OUT 0/4-20mA (24V) LAN and WIFI-interface integrated function to the same time
plus VAT. and shipping
EtherSens Control 24V 2x Analog-IO V1.0
Supply voltage: 24V DC 8 x analog IN 0-5V opt. with ext.Shunt 0/4-20mA opt. with ext. restistance 0-10/24/50V 8 x analog OUT 0/4-20mA (24V) LAN and WIFI-interface integrated function to the same time
plus VAT. and shipping
EtherSens Control 24V 2x Analog-IO V1.1
Supply voltage: 24V DC 8 x Analogue Input (switchable between U, I, differential) 8 x analog OUT 0/4-20mA (24V) LAN and WIFI-interface integrated function to the same time
plus VAT. and shipping
EtherSens Control 24V Analog-/Digital-IO V1.0
Supply voltage: 24V DC 12 x digital IN or OUT 24VDC 400mA free config with software 4 x analog IN 0-5V opt. with ext.Shunt 0/4-20mA opt. with ext. restistance 0-10/24/50V 4 x analog OUT 0/4-20mA (24V) LAN and WIFI-interface integrated function to the same time
plus VAT. and shipping
EtherSens Control 24V Analog-/Digital-IO V1.0 o. LAN
Supply voltage: 24V DC 12 x digital IN or OUT 24VDC 400mA free config with software 4 x analog IN 0-5V opt. with ext.Shunt 0/4-20mA opt. with ext. restistance 0-10/24/50V 4 x analog OUT 0/4-20mA (24V) Only LAN-interface
plus VAT. and shipping
EtherSens Control 24V Analog-/Digital-IO V1.1
Supply voltage: 24V DC 12 x digital IN or OUT 24VDC 400mA free config with software 4 x Analogue Input (switchable between U, I, differential) 4 x analog OUT 0/4-20mA (24V) LAN and WIFI-interface integrated function to the same time
plus VAT. and shipping
EtherSens Control 24V Analog-/Relay-IO
Supply voltage: 24V DC 4 x analog IN 0-5V opt. with ext.Shunt 0/4-20mA opt. with ext. restistance 0-10/24/50V 4 x analog OUT 0/4-20mA (24V) 4 x Relay-OUT 230VAC/16A LAN and WIFI-interface integrated function to the same time
plus VAT. and shipping
EtherSens Control 24V Analog-/Relay-IO V1.1
Supply voltage: 24V DC 4 x Analogue Input (switchable between U, I, differential) 4 x analog OUT 0/4-20mA (24V) 4 x Relay-OUT 230VAC/16A LAN and WIFI-interface integrated function to the same time
plus VAT. and shipping
EtherSens Control 24V Digital-IO
Supply voltage: 24V DC 12 x digital IN or OUT 24VDC 400mA free config with software LAN and WIFI-interface integrated function to the same time
plus VAT. and shipping
EtherSens Control 24V 2x Digital-IO
Supply voltage: 24V DC 24 x digital IN or OUT 24VDC 400mA free config with software LAN and WIFI-interface integrated function to the same time
plus VAT. and shipping
EtherSens Control 24V Digital-/Relay-IO
Supply voltage: 24V DC 12 x digital IN or OUT 24VDC 400mA free config with software 4 x Relay-OUT 230VAC/16A LAN and WIFI-interface integrated function to the same time
plus VAT. and shipping
EtherSens Control 230V Relay-IO
Supply voltage: 230V AC 4 x Relay-OUT 230VAC/16A LAN and WIFI-interface integrated function to the same time
plus VAT. and shipping
EtherSens Control 24V Relay-IO
Supply voltage: 24V DC 4 x Relay-OUT 230VAC/16A LAN and WIFI-interface integrated function to the same time
plus VAT. and shipping
plus VAT. and shipping