Differences between ALF (art.nr.: 9352-ALF) and ALF-UA (art.nr.: 9352-ALF-UA / 9352-ALF-UA-TISCH)

ALF

more...

S7

PPI-Bus
PPI 9.6 KBit/s - 19.2 KBit/s
x
x
x
x
x
x
x
x
x
Multimaster 9.6 KBit/s - 187.5 KBit/s
x
x
x
x
x
x
x
x
MPI-Bus
19.2 KBit/s
x
x
x
x
x
x
x
x
x
187.5 KBit/s
x
x
x
x
x
x
x
x
x
1.5 MBit/s
x
x
x
x
x
x
x
x
Profibus
9.6 KBit/s
x
x
x
x
x
x
x
x
19.2 KBit/s
x
x
x
x
x
x
x
x
x
45.45 KBit/s
x
x
x
x
x
x
x
x
93.75 KBit/s
x
x
x
x
x
x
x
x
187.5 KBit/s
x
x
x
x
x
x
x
x
x
500 KBit/s
x
x
x
x
x
x
x
x
1.5 MBit/s
x
x
x
x
x
x
x
x
3.0 MBit/s
x
x
x
x
x
x
x
x
6.0 MBit/s
x
x
x
x
x
x
x
x
12.0 MBit/s
x
x
x
x
x
x
x
x
Profibus-profile
DP
x(12)
x
x
x
x
x
x
x
x
standard
x(12)
x
x
x
x
x
x
x
x
universal(DP/FMS)
x
x
x
x
x
x
x
x
RS 232
9.6 KBit/s
x(19)
x(19)
19.2 KBit/s
x
x
38.4 KBit/s
x
x
57.6 KBit/s
x(9)
x(9)
115.2 KBit/s
x(9)
x(9)
USB
USB 1.1 (6)
x(1)
x
x(2)
LAN
10/100BaseTx
x(7)
x
x
x
x
WIFI
2.4 GHz
x
TeleService operation
with S7-300/400
x(14)(18)
x(14)(18)
baud rates at TS-operation directly at the PC
9.6 KBit/s
x
x
19.2 KBit/s
x
x
38.4 KBit/s
x(8)
x(8)
57.6 KBit/s
x(8)
x(8)
baud rates at TS-operation directly with a modem
9.6 KBit/s
x
x
19.2 KBit/s
x
x
38.4 KBit/s
x
x
57.6 KBit/s
x
x
115.2 KBit/s
x
x
HMI
9.6 KBit/s
x
x
x(13)
x(13)
x(13)
x(13)
x(13)
x(13)
x(13)
19.2 KBit/s
x
x
x(13)
x(13)
x(13)
x(13)
x(13)
x(13)
x(13)
38.4 KBit/s
x
x
x(13)
x(13)
x(13)
x(13)
x(13)
x(13)
x(13)
57.6 KBit/s
x
x
x(13)
x(13)
x(13)
x(13)
x(13)
x(13)
x(13)
115.2 KBit/s
x
x
x(13)
x(13)
x(13)
x(13)
x(13)
x(13)
x(13)
update
firmware-update
x(10)
x(10)
x(15)
x(15)
x(15)
x(15)
x(15)
x(15)
x(15)
input/online help                  
keypad
x
x
x
x(21)
x(21)
x(21)
x(21)
display
x
x
x
x
x(21)
x(21)
x(21)
x(21)
PD connections (maximum)                  
PLCVCOM
1
1
1
1
1
1
1
1
RFC1006
8
8
32
32
32
AG connections (maximum)
passive subscriber
1
15
15
15
15
15
15
15
15
active subscriber
126
126
126
126
126
126
126
126
126
more functions                  
integrated PLC-firewall
x
x
x
display diagnostic-buffer in the webbrowser
x
x
x
webserver for configuration
x
x
x
x
x
Remote access over existing VPN-channel
x
x
x
x
x
Access via existing WLAN-channel
x
x
x
x
x
status/control variable
x
x
x
x
x
S7 on S7/S5 DB exchange
x
x
x
x
x
S5 on MPI DB exchange
only as S5toMPI
S7 on MPI (Send/Fetch)
x
x
x
x
x
Profinet Gateway
x
x
x
x
x
Time in PLC from NTP-server
x
x
x
x
x
galvanic separation                  
to the bus (screen connected through)
1KV
1KV
1KV
1,5KV
1KV
1,5KV
1,5KV
1,5KV
1,5KV
mounting                  
wall monuting
(with opt. wall mounting-set)
x
x
x
x
upgrading with
CheapConn+cable
x
x
x
x
supports
WIN 98
x
x(3)
x
x
x
x
x
WIN 98 SE
x
x
x
x
x
x
x
x
x
WIN ME
x
x
x
x
x
x
x
x
x
WIN NT
x
x(5)
x(5)
x
x(5)
WIN 2000
x
x
x
x
x
x
x
x
x
WIN XP Home (4)
x
x
x
x
x
x
x
x
x
WIN XP Professional
x
x
x
x
x
x
x
x
x
Vista(32bit)
x
x
x
x
x
x
x
x
x
Win7(32bit)
x
x
x
x
x
x
x
x
x
Win7(64bit)
(22)
x(23)
x(20)
x(20)
x(20)
x(20)
x(20)
x(20)
x(20)
Win8/8.1
(22)
x(23)
x(20)
x(20)
x(20)
x(20)
x(20)
x(20)
x(20)
Win10
(22)
x(23)
x(20)
x(20)
x(20)
x(20)
x(20)
x(20)
x(20)
Win11
(22)
x(23)
x(20)
x(20)
x(20)
x(20)
x(20)
x(20)
x(20)

(1) just with USB-cable plug <-> plug, type A <-> A, item number: 9352.1
(2) just with USB-cable plug <-> plug, type A <-> mini B, item number: 9352.3
(3) only serial communication
(4) Siemens Step7 V5.2 and higher dont run with this operationing system
(5) USB-communication is only possible with the special driver for Win NT
(6) USB 2.0 is backward compatible to 1.1
(7) Cable is designed for direct connection to PC network card socket. It can also be a hub / switch
with uplink port or operated at a hub / switch with automatic detection of assignement and adaptation
(8) only in combination with the MPI-Speed-driver („continously-active“)
(9) Siemens Step7 supports these baud rates only with the MPI-Speed-Utility
(10) Update directly with PC or via Tele-Network if the cable is connected to a device of the
Tele-Network-family (Tele-Link, Tele-Book or Tele-Professional)
(11) only in the mode: MultiMaster-Mode
(12) up to a maximum baud rate of 187.5 KBit/s
(13) In this transmission, the baud rate is irrelevant, because it communicates via a virtual COM-port.
(14) with the use of the TS-adapter / item number: 9350.TS
(15) Update directly with PC and TIC-driver
(18) Operation requires Step 7 with additional software Tele-Service (TS) from Siemens
(19) only at PPI-communication possible
(20) Only with TIC-driver
(21) with integrated webserver possible
(22) No support of Siemens Step7-software possible
(23) Only with USB and with TIC-driver

S5

device type
S5-90U
x
+ext. 24V
+ext. 24V
x
x
x
S5-95U
x
+ext. 24V
+ext. 24V
x
x
x
S5-100U
x
+ext. 24V(3)
+ext. 24V
x
x
x
S5-115U
at 944 + 9359-8
at 944 + 9359-8 + ext. 24V (4)
x
x
x
x
S5-135U
at 928B + 9359-8
at 928B + 9359-8 +ext. 24V (6)
x
x
x
x
S5-155U
x
x
x
x
x
x
S5-AG110S
+9359-5-150 + 9359-4
+ ext. 24V (3)
+9359-5-150 + ext. 24V
S5-AG130W/B
+9359-5-150 + 9359-4
+ ext. 24V (3)
+9359-5-150 + ext. 24V
S5-AG150A/K/S/U
+9359-5-150 + 9359-4
+ ext. 24V (3)
+9359-5-150 + ext. 24V
CP-143
x
x
x
CP-521
+CP521 adapter
       
+CP521 adapter(1)
CP-523
+CP523 adapter
       
+CP523 adapter(1)
CP-525      
+9359-5(1)
CP-526
x
   
x
 
x
CP-527
x
   
x
 
x
CP-528
x
   
x
 
x
CP-544
x (7)
   
x (7)
 
x (7)
CP-5430
x
   
x
 
x
CP-5431
x
   
 
IP-246
x
   
x
 
x
IP-247
x
   
x
 
x
IP-252
x
   
x
 
x
IP-266
 
x
+9359-4(1)
WF-470
SIN-805
+9359-6 + ext. 24V(5)
+9359-6 + ext. 24V(8)
+9359-6(1)
SIN-820
+9359-6 + ext. 24V(5)
+9359-6 + ext. 24V(8)
+9359-6(1)
SIN-840
+9359-6 + ext. 24V(5)
+9359-6 + ext. 24V(8)
+9359-6(1)
SIN-850
+9359-6 + ext. 24V(5)
+9359-6 + ext. 24V(8)
+9359-6(1)
SIN-880
+9359-6 + ext. 24V(5)
+9359-6 + ext. 24V(8)
 
+9359-6(1)
Connection on PC
RS232-port
Ethernet RJ45
Ethernet RJ45 / WLAN/WIFI
USB-port type A
RS232-port
RS232-port
max. prolongation: 300m (UNI-extension) 300m (S5-LAN-extension) +ext. 24V 100m (PG-USB-extension)   300m (UNI-extension)

(1) ISO adapter can not be used because the required supply voltage on the PG interface of the module is not present.
(2) At the CPU 6ES5 102-8MA02 Release 3 is a PG-ISO-Adapter or Netz-Adapter additional required.
(3) With S5-LAN++ from HW V2.3 [2010] the "Netz-Adapter" is no more needed, this version has included current-sources.
(4) With S5-LAN++ from HW V2.3 [2010] no accessories are needed, this version has included current-sources.
(5) With S5-LAN++ from HW V2.3 [2010] the Sinum-Adapter 9359-6-USB is needed.
(6) Only for CPU928B with PG-ISO-Adapter and ext. 24V DC, unless there is an S5-LAN++ from HW V2.3 [2010] used.
(7) CP544 has bolts at the programming-interface. The products do not fit 100% on this interface.
(8) With S5-BRIDGE the Sinum-Adapter 9359-6-USB is needed.

Differences between ALF (art.nr.: 9352-ALF) and ALF-UA (art.nr.: 9352-ALF-UA / 9352-ALF-UA-TISCH)

ALF ALF-UA ALF-UA-TISCH
Assembly / housing Tabletop unit DIN-rail assembly Tabletop unit
Search for access. nodes Simatic-Manager/TIA --- Yes Yes
Support WPS registration Yes --- ---
Easy configuration --- Yes Yes
Restart mandatory between config changes Yes No, just switch No, just switch
Language of the web interface only GB D / GB switchable D / GB switchable
Access-Point/Client at the same time --- Yes Yes
WAN-port can be used in AP-bridge-mode --- Yes Yes
WAN-port can be used in client-bridge-mode --- Yes Yes
USB port for future expansion --- Yes Yes
Passive POE (12V) Yes --- ---

Operating-modes of the ALF-device and their function:

Operating-mode ALF ALF-UA
AP-Router
  • Build a WiFi-network
  • LAN-port and WiFi are in the same subnet
    ⇒ all together communicating devices must be in the same subnet
  • The WAN-port must be another subnet, it will be routed here
  • Build a WiFi-network
  • LAN-port and WiFi are in the same subnet
    ⇒ all together communicating devices must be in the same subnet
  • The WAN-port must be another subnet, it will be routed here
AP-Bridge
  • Build a WiFi-network
  • LAN-port and WiFi are in the same subnet
    ⇒ all together communicating devices must be in the same subnet
  • The WAN-port is without function
  • Build a WiFi-network
  • LAN-port, WAN-port and WiFi are in the same subnet
    ⇒ all together communicating devices must be in the same subnet
Client-Router
  • Connects to existing WiFi-network
  • LAN-port and WiFi must be in the same SubNet
    ⇒ all together communicating devices must be in the same subnet
  • The WAN-port must be another subnet, it will be routed here
  • Connects to existing WiFi-network
  • LAN-port and WiFi must be in the same SubNet
    ⇒ all together communicating devices must be in the same subnet
  • The WAN-port must be another subnet, it will be routed here
Client-Bridge
  • Connects to existing WiFi-network
  • LAN-port and WiFi must be in the same SubNet
    ⇒ all together communicating devices must be in the same subnet
  • The WAN-port is without function
  • Connects to existing WiFi-network
  • LAN-port, WAN-port and WiFi must be in the same SubNet
    ⇒ all together communicating devices must be in the same subnet
24V-supply from the PLC
Produkbild

You want to install your ALF directly in the switch-board and would like to use the 24V of the existing S7-PLC? No problem, connect the open ended side of the Kabelbrücke to the 24V port on your ALF and the bus-side on the MPI- or Profibus of this PLC. Even the ALF is supplied above this PLC.

Operation as an access point
Produkbild

You are on site your plant and should move round the machine and simultaneously control or monitor. No problem, you parametrize ALF as an access-point and connect your S7-LAN or other network-client to him, connect your PC with him and you are online on the PLC.

Operation as a WLAN-client
Produkbild

You are on site your plant and should move round the machine and simultaneously control or monitor. WLAN is reachable, but your PC is not able to provide WLAN. No problem, you parametrize ALF as a client and connect him to the PC and join the reachable WLAN and you are online on the PLC.

Operation as bridge
Produkbild

You have two or more clients which should communicate together without LAN-cable-connection? No problem, you connect a "Access-Point" configured ALF to this device and to the other device a "Client" configured ALF. Then connect the "Client" with the "Access-Point" and the device are able to communicate together.

No direct connected LAN-client required
Produkbild

You have some LAN-clients and want to communicate via WLAN with them? No problem, you connect ALF to a switch and you are able to communicate with all this clients. You don´t need a direct connect client.

Easiest configuration by included webserver
Produkbild

To configure ALF you don´t need additional driver or special cables, you connect your PC via LAN or WLAN with ALF and over the integrated webserver you can configure the needed function.

Integrated dhcp-server
Produkbild

You use your PC in your company network with DHCP, so you don´t have to care the everlasting setting of the ip-address. No problem, ALF also can be configured as a DHCP-server and assigns you accessing to the device via LAN or WLAN an ip-address from a predefined address range.

Autonegotiation on RJ-45
Produkbild

You need ALF to connect to a reachable WLAN, but only have a patch-cable? No problem, ALF provides "autonegotiation" and this means that he recognises a connected cable (patch-cable or cross-over-cable) and surround the pinning according to the cable, so a communication is possible.

Integrated firewall
Produkbild

You use ALF as a WLAN-router to connect your PC with the internet. No Problem, this Sie nutzen ALF als WLAN-Router um Ihren PC ins Internet zu bringen. Kein Problem, ALF masters this task without problems. Its built-in firewall ensures that no hacker from outside changes your configuration or moves in your network.

All prices plus costs of delivery, shipping insurance and VAT.
All prices plus costs of delivery, shipping insurance and VAT.
All prices plus costs of delivery, shipping insurance and VAT.

Automatic-mode

Versionstory

Other downloads

Extension

Support-videos