EVENT-MODEM
Long distance report- and information systems
Attention:
Eventmodem-devices are obsolete! MESSI replaces the Eventmodem-devices.
You can find more about this device on the product-page of the device.
- Digital in-/outputs, each one configurable as opener or closer
- 8 report targets per input
- Fax, e-mail, SMS, Pager and Voice (fixed report texts)
more...
Attention:
Eventmodem-devices are obsolete! MESSI replaces the Eventmodem-devices.
You can find more about this device on the product-page of the device.
- Digital in-/outputs, each one configurable as opener or closer
- 8 report targets per input
- Fax, e-mail, SMS, Pager and Voice (fixed report texts)
Analogue:
|
GSM:
|
Event-Modem A200
|
Event-Modem G200
|
Event-Modem A242
composed of Event-Modem A200 and X332
|
Event-Modem G242
composed of Event-Modem G200 and X332
|
Direct Voice-speach-output with MESSI NG 3G
Transmission of fault messages as a voice message to several participants
MESSI NG 3G can send stored-voice-messages to specific recipients depending on the defined input and signal status. To do this, the specified phone-numbers are called according to the phone-number-plan and then the digitized voice-message is transmitted.
Depending on whether the message has been acknowledged or not, the next participant in the numbering-plan will be informed.
Let yourself for example, giving water-levels over the phone, MESSI NG 3G will do this for you.
MESSI NG 3G can send stored-voice-messages to specific recipients depending on the defined input and signal status. To do this, the specified phone-numbers are called according to the phone-number-plan and then the digitized voice-message is transmitted.
Depending on whether the message has been acknowledged or not, the next participant in the numbering-plan will be informed.
Let yourself for example, giving water-levels over the phone, MESSI NG 3G will do this for you.
Direct Fax
By direct dialling up the fax machine a message is carried out to a fax-receiver. If a connection comes off the message will be transmitted.
Remote Maintenance via keyboard and voice
The MESSI remote-station will be called directly by integrated mobile-phone. If a connection comes off, digital In- and Outputs for teleswitching will be transmitted. Each device
can both transmit state of things and accordingly receive switch signals.
Remote switching with MESSI to MESSI
The MESSI will be called by conventional Telephone or by mobile-phone. With a direct voice message and DTMF-tone dialling the corresponding output will be set-up. If a switching
operation has come off a speech output will confirm it.
Message via SMS (SMSC)
A SMS to a mobile phone is basically send by SMSC. Within the GSM-network it takes place via on-net SMSC. Thereby it’s unimportant in which mobile network the receiver is.
The message is activated by:
- digital contacts (relays, motion detector...)
- serial interface (PLC, PC, Microcontroller ...) bitserial (PLC)
The detection system transmits the SMS to the mobile network operator. The mobile network operator provides the SMS to the mobile phone. Optionally the detection system dials the mobile phone to „wake up“ the receiver or to initiate the confirmation handling.
The message is activated by:
- digital contacts (relays, motion detector...)
- serial interface (PLC, PC, Microcontroller ...) bitserial (PLC)
The detection system transmits the SMS to the mobile network operator. The mobile network operator provides the SMS to the mobile phone. Optionally the detection system dials the mobile phone to „wake up“ the receiver or to initiate the confirmation handling.
Data logging
Cyclic data logging or data logging on occasion is realisable. The log data will be transmitted e.g. once a day via e-mail.
Special data logger functions can be implemented on request and are not part of the basis functions.
Special data logger functions can be implemented on request and are not part of the basis functions.
To switch a MESSI-output via SMS
Switching an output via SMS is an integrated function of the MESSI. Herewith the switching operation will be secure and comprehensible from afar.
Supply voltage: | 24V DC +/- 20% |
Power consumption: | 4 watt |
Display: | Web-Browser |
Handling/Configuration: | 4 DIP-Switch for operating states |
Interfaces: |
to the PLC:
digital in-/outputsanalogue in-/outputs
to the PD/PC:
RS232RS485
others:
- |
Integrated modem: | analogue modem V92 / GSM-modem |
Operating temperature: | -20 - +60°C |
Case: | plastic case for DIN-rail mounting |
Dimensions: | 110 x 125 x 60 mm |
Scope of delivery: |
Eventmodem Cable 9pin 1to1 Attention: telephone-cable / GSM-antenna not included in scope of delivery |
All prices plus costs of delivery, shipping insurance and VAT.
accessories:
244,00 €
plus VAT. and shipping
plus VAT. and shipping
11,00 €
plus VAT. and shipping
plus VAT. and shipping
59,00 €
plus VAT. and shipping
plus VAT. and shipping
22,00 €
plus VAT. and shipping
plus VAT. and shipping
25,00 €
plus VAT. and shipping
plus VAT. and shipping
25,00 €
plus VAT. and shipping
plus VAT. and shipping
25,00 €
plus VAT. and shipping
plus VAT. and shipping
25,00 €
plus VAT. and shipping
plus VAT. and shipping
25,00 €
plus VAT. and shipping
plus VAT. and shipping
25,00 €
plus VAT. and shipping
plus VAT. and shipping
25,00 €
plus VAT. and shipping
plus VAT. and shipping
29,00 €
plus VAT. and shipping
plus VAT. and shipping
All prices plus costs of delivery, shipping insurance and VAT.
All prices plus costs of delivery, shipping insurance and VAT.