Cookies helfen uns bei der Bereitstellung unserer Dienste. Durch die Nutzung unserer Dienste erklären Sie sich damit einverstanden, dass wir Cookies setzen.
Cookies help us in providing our services. By using our services, you agree that we set cookies.
OK
LAN - Process Informatik Entwicklungsgesellschaft mbH

LAN


S7

PPI-Bus
PPI 9.6 KBit/s - 19.2 KBit/s
x
x
x
x
x
x
x
x
x
Multimaster 9.6 KBit/s - 187.5 KBit/s
x
x
x
x
x
x
x
x
MPI-Bus
19.2 KBit/s
x
x
x
x
x
x
x
x
x
187.5 KBit/s
x
x
x
x
x
x
x
x
x
1.5 MBit/s
x
x
x
x
x
x
x
x
Profibus
9.6 KBit/s
x
x
x
x
x
x
x
x
19.2 KBit/s
x
x
x
x
x
x
x
x
x
45.45 KBit/s
x
x
x
x
x
x
x
x
93.75 KBit/s
x
x
x
x
x
x
x
x
187.5 KBit/s
x
x
x
x
x
x
x
x
x
500 KBit/s
x
x
x
x
x
x
x
x
1.5 MBit/s
x
x
x
x
x
x
x
x
3.0 MBit/s
x
x
x
x
x
x
x
x
6.0 MBit/s
x
x
x
x
x
x
x
x
12.0 MBit/s
x
x
x
x
x
x
x
x
Profibus-profile
DP
x(12)
x
x
x
x
x
x
x
x
standard
x(12)
x
x
x
x
x
x
x
x
universal(DP/FMS)
x
x
x
x
x
x
x
x
RS 232
9.6 KBit/s
x(19)
x(19)
19.2 KBit/s
x
x
38.4 KBit/s
x
x
57.6 KBit/s
x(9)
x(9)
115.2 KBit/s
x(9)
x(9)
USB
USB 1.1 (6)
x(1)
x
x(2)
LAN
10/100BaseTx
x(7)
x
x
x
x
WIFI
2.4 GHz
x
TeleService operation
with S7-300/400
x(14)(18)
x(14)(18)
baud rates at TS-operation directly at the PC
9.6 KBit/s
x
x
19.2 KBit/s
x
x
38.4 KBit/s
x(8)
x(8)
57.6 KBit/s
x(8)
x(8)
baud rates at TS-operation directly with a modem
9.6 KBit/s
x
x
19.2 KBit/s
x
x
38.4 KBit/s
x
x
57.6 KBit/s
x
x
115.2 KBit/s
x
x
HMI
9.6 KBit/s
x
x
x(13)
x(13)
x(13)
x(13)
x(13)
x(13)
x(13)
19.2 KBit/s
x
x
x(13)
x(13)
x(13)
x(13)
x(13)
x(13)
x(13)
38.4 KBit/s
x
x
x(13)
x(13)
x(13)
x(13)
x(13)
x(13)
x(13)
57.6 KBit/s
x
x
x(13)
x(13)
x(13)
x(13)
x(13)
x(13)
x(13)
115.2 KBit/s
x
x
x(13)
x(13)
x(13)
x(13)
x(13)
x(13)
x(13)
update
firmware-update
x(10)
x(10)
x(15)
x(15)
x(15)
x(15)
x(15)
x(15)
x(15)
input/online help                  
keypad
x
x
x
x(21)
x(21)
x(21)
x(21)
display
x
x
x
x
x(21)
x(21)
x(21)
x(21)
PD connections (maximum)                  
PLCVCOM
1
1
1
1
1
1
1
1
RFC1006
8
8
32
32
32
AG connections (maximum)
passive subscriber
1
15
15
15
15
15
15
15
15
active subscriber
126
126
126
126
126
126
126
126
126
more functions                  
integrated PLC-firewall
x
x
x
display diagnostic-buffer in the webbrowser
x
x
x
webserver for configuration
x
x
x
x
x
Remote access over existing VPN-channel
x
x
x
x
x
Access via existing WLAN-channel
x
x
x
x
x
status/control variable
x
x
x
x
x
S7 on S7/S5 DB exchange
x
x
x
x
x
S5 on MPI DB exchange
only as S5toMPI
S7 on MPI (Send/Fetch)
x
x
x
x
x
Profinet Gateway
x
x
x
x
x
Time in PLC from NTP-server
x
x
x
x
x
galvanic separation                  
to the bus (screen connected through)
1KV
1KV
1KV
1,5KV
1KV
1,5KV
1,5KV
1,5KV
1,5KV
mounting                  
wall monuting
(with opt. wall mounting-set)
x
x
x
x
upgrading with
CheapConn+cable
x
x
x
x
supports
WIN 98
x
x(3)
x
x
x
x
x
WIN 98 SE
x
x
x
x
x
x
x
x
x
WIN ME
x
x
x
x
x
x
x
x
x
WIN NT
x
x(5)
x(5)
x
x(5)
WIN 2000
x
x
x
x
x
x
x
x
x
WIN XP Home (4)
x
x
x
x
x
x
x
x
x
WIN XP Professional
x
x
x
x
x
x
x
x
x
Vista(32bit)
x
x
x
x
x
x
x
x
x
Win7(32bit)
x
x
x
x
x
x
x
x
x
Win7(64bit)
(22)
x(23)
x(20)
x(20)
x(20)
x(20)
x(20)
x(20)
x(20)
Win8/8.1
(22)
x(23)
x(20)
x(20)
x(20)
x(20)
x(20)
x(20)
x(20)
Win10
(22)
x(23)
x(20)
x(20)
x(20)
x(20)
x(20)
x(20)
x(20)
Win11
(22)
x(23)
x(20)
x(20)
x(20)
x(20)
x(20)
x(20)
x(20)

(1) just with USB-cable plug <-> plug, type A <-> A, item number: 9352.1
(2) just with USB-cable plug <-> plug, type A <-> mini B, item number: 9352.3
(3) only serial communication
(4) Siemens Step7 V5.2 and higher dont run with this operationing system
(5) USB-communication is only possible with the special driver for Win NT
(6) USB 2.0 is backward compatible to 1.1
(7) Cable is designed for direct connection to PC network card socket. It can also be a hub / switch
with uplink port or operated at a hub / switch with automatic detection of assignement and adaptation
(8) only in combination with the MPI-Speed-driver („continously-active“)
(9) Siemens Step7 supports these baud rates only with the MPI-Speed-Utility
(10) Update directly with PC or via Tele-Network if the cable is connected to a device of the
Tele-Network-family (Tele-Link, Tele-Book or Tele-Professional)
(11) only in the mode: MultiMaster-Mode
(12) up to a maximum baud rate of 187.5 KBit/s
(13) In this transmission, the baud rate is irrelevant, because it communicates via a virtual COM-port.
(14) with the use of the TS-adapter / item number: 9350.TS
(15) Update directly with PC and TIC-driver
(18) Operation requires Step 7 with additional software Tele-Service (TS) from Siemens
(19) only at PPI-communication possible
(20) Only with TIC-driver
(21) with integrated webserver possible
(22) No support of Siemens Step7-software possible
(23) Only with USB and with TIC-driver
S7-PLC over LAN
Produkbild

Communication with S7-PLC via Ethernet, just how and with what?
Data-communication with S7-PLC from PC or other devices via network, which interface is required. Questions you don't have to worry about. With "S7 over LAN" you get the right interface-products for PPI, MPI and Profibus.
Which one you use then is up to you.

All prices plus costs of delivery, shipping insurance and VAT.
All prices plus costs of delivery, shipping insurance and VAT.
All prices plus costs of delivery, shipping insurance and VAT.