ProfiNet - analysis/diagnosis/monitoring












for Din-rail-mounting
Features:- Non-reactive recording of Ethernet communication
- Secure and passive decoupling of telegrams
- Monitors all OSI layers starting from layer 2 and monitors packets of all sizes and types and VLAN traffic
- For 10 or 100Mbit/s
- To monitoring-PC with WIFI 2,4 GHz
more...
ARTNR: 7050
ProfiNet - analysis/burglary/failure/life-cycle
| EAN number: | 4260363249133 | |
| HS-code: | 85176200 | |
| Weight: | 0.17 kg |
- Non-reactive recording of Ethernet communication
- Secure and passive decoupling of telegrams
- Monitors all OSI layers starting from layer 2 and monitors packets of all sizes and types and VLAN traffic
- For 10 or 100Mbit/s
- To monitoring-PC with WIFI 2,4 GHz
- No influence on Ethernet transmission in case of power failure
- No influence on the ProfiNet-system/-timing (real-time behavior)
- No security risks
- Exact timestamps
- Plug directly into the ProfiNet cable
- Installation in less than 1 minute
- No Switch needed
- Invisible to switch/devices
- Logging error-protocols
- Analysis of the participants, bus overview
- Determination of the probability of default of participants
- Activity-documentation
- Automatic detection of every PN-network
- Monitoring (e-mail-message)
- Burglary
- Unauthorized PN-participants
- Malfunction
- Failure/missing PN-participants
- Abnormalities
- Creeping disorder
- Extendable with 3rd LAN-socket for connection of recording-PC via LAN-cable, if WiFi is not permitted/possible
Identify devices that are likely to fail in the near future.
Detect defective devices that no longer respond to PN protocols.
Defective devices are reported by email and logged.
No long troubleshooting thanks to exact station information.
Exact analysis of your Profinet members.
Addresses, configurations and other data can be recorded directly.
See immediately possible conflicts due to the configuration.
Detection and logging of unauthorized access in the defined Profinet
Attempted break-ins and access to the network are recognized immediately and e.g. reported by email
Logging of all accesses in the network for historical processing
Possible data-storage USB-stick or FTP-server via USB-network-stick.
Recognize cable breakage, contact problems and line faults.
Retransmissions and failures are logged and reported.
Early acting before total failure of the participant.
Identify impending failures in your Profinet.
Creeping aging will be displayed to you very detailed.
The Profinet-Watchdog give you the change to react before something happens.
Detect intrusions and anomalies on your ProfiNet.
Early detection of malfunction and failures and malfunctions.
Easy installation, plug and play double socket.
Detect intrusions and anomalies on your ProfiNet.
Early detection of malfunction and failures and malfunctions.
Easy installation, plug and play double socket.
Detection and logging of unauthorized access in the defined Profinet
Attempted break-ins and access to the network are recognized immediately and e.g. reported by email
Logging of all accesses in the network for historical processing
Possible data-storage USB-stick or FTP-server via USB-network-stick.
Recognize cable breakage, contact problems and line faults.
Retransmissions and failures are logged and reported.
Early acting before total failure of the participant.
Identify impending failures in your Profinet.
Creeping aging will be displayed to you very detailed.
The Profinet-Watchdog give you the change to react before something happens.
You may not use WIFI in your environment?
Connect the USB-ETHERNET-adapter to the ProfiNet-WATCHDOG's USB-port and create another Ethernet-socket.
Connect your PC directly with LAN-cable to the ProfiNet WATCHDOG.
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
Applications
Analysis technicDetermination of physical measured variables
Data-backup of PLC
EtherSensNetworked via LAN - WIFI - LTE
Worldwide access from any device possible
Internal and external data-storage
Simple rail-mounting
Remote maintenance / Remote access
Internet-coupling/communication
Programming adapter S5
Programming adapter S7
PD-interface-multiplexerInterface-multiplexer for the Programming Device (PD) of the programmable logic controller (PLC)
Bussystem S5 (BT-777 / DUPLINE)Accessories for bus systems of the S5
WIFI - PLC
WLAN/WIFI-SETsService-suitcase for couppling to a PLC over LAN/WLAN incl. all accessories
Panel connectionPanel couplings around S5/7-PLCs
PLC-Coupling
Error messagingSend disorders by fax, sms, e-mail, voice
Industrie 4.0 toolsTools around industry 4.0
PLC-communication-driver
Programming-software PG-2000 Step5 & Step7STEP5/7 for Windows-PCs +++ Original S5D-/S7P-file-format +++ Also for Win10/11
Memory modules / PrommerAll about memory modules and the corresponding programming devices
RetrofitUpgrading older production facilities for the future
and Industry 4.0
plus VAT. and shipping
S7-BRIDGE
Online with S7-PLC wo. cables +++ S7-adapter PPI/MPI/PROFIBUS/PN +++ No WIFI-infrastructure +++ Integrated access-point +++ PPI/MPI/DP/PN - LAN - WIFI
plus VAT. and shipping





PI-Service-Mail

ask technician:
same day