S5-3964R-LAN RS232-version
Communicate with 3964R-client with S7-TCPIP
Communication with 3964/9364R-client with
S7-TCPIP
inclusive adapter cable
(15pin female <=> 9pin male)
Your visualisation-software does not support a 3964R-protocol, but you have to apply this package? No problem, connect the 3964R-LAN to your CP and activate the RFC1006-emulation in the module. Now your software gets the data from the module via RFC1006, which in turn communicates with the assembly via 3964R.
variants:
ARTNR: 9359-RK-RS
S5-3964R-LAN RS232-version
971,00 € plus VAT. and shipping
ARTNR: 9359-RK-RS
S5-3964R-LAN RS232-version
EAN number: | 4260363243889 | |
HS-code: | 85444290 | |
Weight: | 0.1 kg |
Your visualisation-software does not support a 3964R-protocol, but you have to apply this package? No problem, connect the 3964R-LAN to your CP and activate the RFC1006-emulation in the module. Now
your software gets the data from the module via RFC1006, which in turn communicates with the assembly via 3964R.
Visualisation via 3964R-interface without using the protocol itself
Your visualisation-software does not support a 3964R-protocol, but you have to apply this package? No problem, connect the 3964R-LAN to your CP and activate the RFC1006-emulation in the module. Now
your software gets the data from the module via RFC1006, which in turn communicates with the assembly via 3964R.
Extension of a 3964R-line via LAN
There is a control with CP524 in your outstation and the communication partner of the CP has moved locally. Connecting path is a LAN-network. So each of both participants gets a 3964R-LAN and after
input of the partner’s IP-address a coupling via LAN will be configured.
PLC coupling (data exchange between PLC’s)
Your pumping stations report the water levels of the central control via telephone network. The central office itself can of course transmit commands/messages to the substations as well. Therefore
no dedicated line is required, it’s sufficient when the stations connect via network (DSL-router).
With the S5-H1-PG-LAN you would be able to use the H1-path-selection over the S5-LAN++ and communicate with all PLCs in the H1-bus. You don´t have to connect serial to the CP, you can do this easy over your network.
Remote maintenance of your S5-PLC via LAN / Internet
You have access to a on-site network and your PLC has no LAN-connection? No problem, plug the S5-LAN on the PLC and you will have immediate access to the PLC from afar.
Programming of S5-PLC’s via LAN
You would like to respond to your S5-PLC via LAN, but not integrate an Ethernet-CP? No problem, plug the S5-LAN++ on the PD-interface and access via LAN.
Communication with Win98 – XP/Vista/7/8/10/11 via network to S5-PLC
You still have a PC with Win98 and a MS-DOS-based Step5-package and would like to go Online on your S5-PLC via LAN? No problem, the provided virtual Com-Port PLCVCom emulates a COM-port on your PC
with which you go Online. Even your MS-DOS-based Step5-software on this WIN98-PC can use this virtual Com-Port. With a patchtool for the Siemens Step5-software, which is provided as well, nothing
else stands in your way to communicate via LAN.
Watching of S5- PLC’s with panel for S7-PLC
Your panel only has a LAN-socket as PLC-interface and supports only S7-RFC1006, no problem. Connect this socket with the S5-LAN++ and plug it directly on the PD-interface of the PLC. The S5-LAN++
performs adverse your panel as a S7-PLC although you receive the data from the S5-PLC. Then access to the variables and data of the S5-PLC is already available.
Watching of S5-PLC’s via LAN without Ethernet-CP
Your panel only has a LAN-socket as PLC-interface, no problem. Connect this socket with the S5-LAN++ and plug it directly on the PD-interface of the PLC. Then access to the variables and data of
the PLC is already available.
Supply voltage: | 24V DC +/- 20% |
Power consumption: | 2 watt |
Display: | status-LED |
Handling/Configuration: |
reset-switch-key (factory setting) S5-LAN Manager |
Interfaces: |
to the PLC:
RS232 TxD, RxD and GND
to the PD/PC:
10/100BaseTX RJ45-ethernet jack |
Operating system: |
Configuration and operation via virtual COM-interface: MS-Windows XP/2000/7/8/10/11/Server Operation via TCP/IP server: any operating system with a TCP/IP stack |
Operating temperature: | 0 - 55°C |
Case: | ABS-plastic case |
Dimensions: | 42 x 15 x 65 mm |
Scope of delivery: |
S5-LAN++-module Power connector 2pins small |
All prices plus costs of delivery, shipping insurance and VAT.
accessories:
59,00 €
plus VAT. and shipping
plus VAT. and shipping
15,00 €
plus VAT. and shipping
plus VAT. and shipping
9636-TCPIP.02M
Patch-cable 0.25m, Cat5e, shielded
RJ45 plug <=> RJ45 plug, 1:1
Patch-cable 0.25m, Cat5e, shielded
RJ45 plug <=> RJ45 plug, 1:1
9636-CROSS
Cross-cable 3m Cat5+, shielded
RJ45 plug <=> RJ45 plug, twisted pinning
Cross-cable 3m Cat5+, shielded
RJ45 plug <=> RJ45 plug, twisted pinning
9636-TCPIP
Patch-cable 3m, Cat5+, shielded
RJ45 plug <=> RJ45 plug, 1:1
Patch-cable 3m, Cat5+, shielded
RJ45 plug <=> RJ45 plug, 1:1
4,00 €
plus VAT. and shipping
plus VAT. and shipping
9391-USB
USB-powercable for 24V DC, max. 3W
USB-plug type A to 2 open braids 24V DC, maximum current: 125mA (for PC 100mA) length: 5m
USB-powercable for 24V DC, max. 3W
USB-plug type A to 2 open braids 24V DC, maximum current: 125mA (for PC 100mA) length: 5m
95,00 €
plus VAT. and shipping
plus VAT. and shipping
All prices plus costs of delivery, shipping insurance and VAT.
9359-RK-RS
S5-3964R-LAN RS232-version
Communication with 3964/9364R-client with S7-TCPIP inclusive adapter cable (15pin female <=> 9pin male)
S5-3964R-LAN RS232-version
Communication with 3964/9364R-client with S7-TCPIP inclusive adapter cable (15pin female <=> 9pin male)
971,00 €
plus VAT. and shipping
plus VAT. and shipping
9359-LAN
S5-LAN++
Industrial Ethernet <> S5 PD-interface (TTY) Including Gateway Plus and S7-TCP / IP functions
S5-LAN++
Industrial Ethernet <> S5 PD-interface (TTY) Including Gateway Plus and S7-TCP / IP functions
452,00 €
plus VAT. and shipping
plus VAT. and shipping
924,00 €
plus VAT. and shipping
plus VAT. and shipping
9359-LAN-RS
S5-LAN++ RS232-version
Industrial Ethernet <=> S5 PD-interface (RS232), inclusive adapter cable (15pin female <=> 9pin male)
S5-LAN++ RS232-version
Industrial Ethernet <=> S5 PD-interface (RS232), inclusive adapter cable (15pin female <=> 9pin male)
555,00 €
plus VAT. and shipping
plus VAT. and shipping
866,00 €
plus VAT. and shipping
plus VAT. and shipping
567,00 €
plus VAT. and shipping
plus VAT. and shipping
693,00 €
plus VAT. and shipping
plus VAT. and shipping
2185,00 €
plus VAT. and shipping
plus VAT. and shipping
All prices plus costs of delivery, shipping insurance and VAT.
9359-LAN-RS
S5-LAN++ RS232-version
Industrial Ethernet <=> S5 PD-interface (RS232), inclusive adapter cable (15pin female <=> 9pin male)
S5-LAN++ RS232-version
Industrial Ethernet <=> S5 PD-interface (RS232), inclusive adapter cable (15pin female <=> 9pin male)
555,00 €
plus VAT. and shipping
plus VAT. and shipping
59,00 €
plus VAT. and shipping
plus VAT. and shipping
9352-LANCON
S7-LAN connector for Siemens S7 PLC controller
Network-connection for the S7-200/300/400-PLC +++ S7-adapter PPI/MPI/PROFIBUS +++ Of developer and manufacturer +++ Smallest Ethernet-gateway S7 +++ Network for each S7-PLC +++ Fast commissioning +++ Replacement for CP343-1/443-1
S7-LAN connector for Siemens S7 PLC controller
Network-connection for the S7-200/300/400-PLC +++ S7-adapter PPI/MPI/PROFIBUS +++ Of developer and manufacturer +++ Smallest Ethernet-gateway S7 +++ Network for each S7-PLC +++ Fast commissioning +++ Replacement for CP343-1/443-1
423,00 €
plus VAT. and shipping
plus VAT. and shipping
9352-ALF-UA
ALF-UA high-speed WIFI-Router for Din-Rail-mounting Obsolete
Successor: CONNECT-Router for Din-Rail-mounting (Art.No: 9354-CONNECT-HS-ROUTER)
Industrial WIFI-Router for Unified Access Integrated USB-port Basic-plattform, functionality with software-options expandable One-click mounting
ALF-UA high-speed WIFI-Router for Din-Rail-mounting Obsolete
Successor: CONNECT-Router for Din-Rail-mounting (Art.No: 9354-CONNECT-HS-ROUTER)
Industrial WIFI-Router for Unified Access Integrated USB-port Basic-plattform, functionality with software-options expandable One-click mounting
0,00 €
plus VAT. and shipping
plus VAT. and shipping
Automatic-mode
Main downloads
Versionstory
- Release-docu 3964R-LAN-firmware
- Release-docu ASCII-LAN-firmware
- Release-docu Multi-VCom
- Release-docu PLCVCom
- Release-docu S5-H1-PG-LAN-firmware
- Release-docu S5-LAN++-firmware
- Release-docu S5-LAN-Manager
- Release-docu S5-LAN-PATH-firmware
- Release-docu S5-Patch
- Release-docu S5-PG-LAN-firmware
- Release-docu S5-VCom