LAN
products
S7-LAN
smallest simatic S7 ethernet gateway with PD-socket, multifunctional, 1 adapter for all PPI, MPI and Profibus applications
with ext. 24V-connector
easy remote maintenance over internet
smallest simatic S7 ethernet gateway with PD-socket, multifunctional, 1 adapter for all PPI, MPI and Profibus applications
with ext. 24V-connector
easy remote maintenance over internet
MPI-LAN
S7-cable PPI/MPI/PROFIBUS +++ Ethernet-gateway S7 as cable +++ Network for each S7-PLC +++ Parallel LAN access +++ Ethernet for each S7-PLC
S7-cable PPI/MPI/PROFIBUS +++ Ethernet-gateway S7 as cable +++ Network for each S7-PLC +++ Parallel LAN access +++ Ethernet for each S7-PLC
S7-BRIDGE
Online with S7-PLC wo. cables +++ S7-adapter Ppi/Mpi/Profibus/Pn +++ No wifi-infrastructure +++ Integrated access-point +++ Ppi/Mpi/Dp/Pn - Lan - Wifi
Online with S7-PLC wo. cables +++ S7-adapter Ppi/Mpi/Profibus/Pn +++ No wifi-infrastructure +++ Integrated access-point +++ Ppi/Mpi/Dp/Pn - Lan - Wifi
S7-GATE
S7-adapter PPI/MPI/PROFIBUS +++ including PLC-firewall +++ Of developer and manufacturer +++ Smallest Ethernet-gateway S7 +++ Network for each S7-PLC +++ Fast commissioning +++ Replacement for CP343-1/443-1
S7-adapter PPI/MPI/PROFIBUS +++ including PLC-firewall +++ Of developer and manufacturer +++ Smallest Ethernet-gateway S7 +++ Network for each S7-PLC +++ Fast commissioning +++ Replacement for CP343-1/443-1
S7-LAN++
S7-LAN++ Connector with integrated firewall for Siemens S7-PLCs
S7-LAN++ Connector with integrated firewall for Siemens S7-PLCs
S7
PPI-Bus | |||||||||
PPI 9.6 KBit/s - 19.2 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
Multimaster 9.6 KBit/s - 187.5 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
MPI-Bus | |||||||||
19.2 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
187.5 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
1.5 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
Profibus | |||||||||
9.6 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
19.2 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
45.45 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
93.75 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
187.5 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
500 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
1.5 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
3.0 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
6.0 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
12.0 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
Profibus-profile | |||||||||
DP |
x(12)
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
standard |
x(12)
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
universal(DP/FMS) |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
RS 232 | |||||||||
9.6 KBit/s |
x(19)
|
x(19)
|
|||||||
19.2 KBit/s |
x
|
x
|
|||||||
38.4 KBit/s |
x
|
x
|
|||||||
57.6 KBit/s |
x(9)
|
x(9)
|
|||||||
115.2 KBit/s |
x(9)
|
x(9)
|
|||||||
USB | |||||||||
USB 1.1 (6) |
x(1)
|
x
|
x(2)
|
||||||
LAN | |||||||||
10/100BaseTx |
x(7)
|
x
|
x
|
x
|
x
|
||||
WIFI | |||||||||
2.4 GHz |
x
|
||||||||
TeleService operation | |||||||||
with S7-300/400 |
x(14)(18)
|
x(14)(18)
|
|||||||
baud rates at TS-operation directly at the PC | |||||||||
9.6 KBit/s |
x
|
x
|
|||||||
19.2 KBit/s |
x
|
x
|
|||||||
38.4 KBit/s |
x(8)
|
x(8)
|
|||||||
57.6 KBit/s |
x(8)
|
x(8)
|
|||||||
baud rates at TS-operation directly with a modem | |||||||||
9.6 KBit/s |
x
|
x
|
|||||||
19.2 KBit/s |
x
|
x
|
|||||||
38.4 KBit/s |
x
|
x
|
|||||||
57.6 KBit/s |
x
|
x
|
|||||||
115.2 KBit/s |
x
|
x
|
|||||||
HMI | |||||||||
9.6 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
19.2 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
38.4 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
57.6 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
115.2 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
update | |||||||||
firmware-update |
x(10)
|
x(10)
|
x(15)
|
x(15)
|
x(15)
|
x(15)
|
x(15)
|
x(15)
|
x(15)
|
input/online help | |||||||||
keypad |
x
|
x
|
x
|
x(21)
|
x(21)
|
x(21)
|
x(21)
|
||
display |
x
|
x
|
x
|
x
|
x(21)
|
x(21)
|
x(21)
|
x(21)
|
|
PD connections (maximum) | |||||||||
PLCVCOM |
1
|
1
|
1
|
1
|
1
|
1
|
1
|
1
|
|
RFC1006 |
8
|
8
|
32
|
32
|
32
|
||||
AG connections (maximum) | |||||||||
passive subscriber |
1
|
15
|
15
|
15
|
15
|
15
|
15
|
15
|
15
|
active subscriber |
126
|
126
|
126
|
126
|
126
|
126
|
126
|
126
|
126
|
more functions | |||||||||
integrated PLC-firewall |
|
|
x
|
x
|
x
|
||||
display diagnostic-buffer in the webbrowser |
|
|
x
|
x
|
x
|
||||
webserver for configuration |
x
|
x
|
x
|
x
|
x
|
||||
Remote access over existing VPN-channel |
x
|
x
|
x
|
x
|
x
|
||||
Access via existing WLAN-channel |
x
|
x
|
x
|
x
|
x
|
||||
status/control variable |
x
|
x
|
x
|
x
|
x
|
||||
S7 on S7/S5 DB exchange |
x
|
x
|
x
|
x
|
x
|
||||
S5 on MPI DB exchange |
only as S5toMPI
|
||||||||
S7 on MPI (Send/Fetch) |
x
|
x
|
x
|
x
|
x
|
||||
Profinet Gateway |
x
|
x
|
x
|
x
|
x
|
||||
Time in PLC from NTP-server |
x
|
x
|
x
|
x
|
x
|
||||
galvanic separation | |||||||||
to the bus (screen connected through) |
1KV
|
1KV
|
1KV
|
1,5KV
|
1KV
|
1,5KV
|
1,5KV
|
1,5KV
|
1,5KV
|
mounting | |||||||||
wall monuting (with opt. wall mounting-set) |
x
|
x
|
x
|
x
|
|||||
upgrading with | |||||||||
CheapConn+cable |
x
|
x
|
x
|
x
|
|||||
supports | |||||||||
WIN 98 |
x
|
x(3)
|
x
|
x
|
x
|
x
|
x
|
||
WIN 98 SE |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
WIN ME |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
WIN NT |
x
|
x(5)
|
x(5)
|
x
|
x(5)
|
||||
WIN 2000 |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
WIN XP Home (4) |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
WIN XP Professional |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
Vista(32bit) |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
Win7(32bit) |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
Win7(64bit) |
(22)
|
x(23)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
Win8/8.1 |
(22)
|
x(23)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
Win10 |
(22)
|
x(23)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
Win11 |
(22)
|
x(23)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
(1) just with USB-cable plug <-> plug, type A <-> A, item number: 9352.1 (2) just with USB-cable plug <-> plug, type A <-> mini B, item number: 9352.3 (3) only serial communication (4) Siemens Step7 V5.2 and higher dont run with this operationing system (5) USB-communication is only possible with the special driver for Win NT (6) USB 2.0 is backward compatible to 1.1 (7) Cable is designed for direct connection to PC network card socket. It can also be a hub / switch with uplink port or operated at a hub / switch with automatic detection of assignement and adaptation (8) only in combination with the MPI-Speed-driver („continously-active“) (9) Siemens Step7 supports these baud rates only with the MPI-Speed-Utility (10) Update directly with PC or via Tele-Network if the cable is connected to a device of the Tele-Network-family (Tele-Link, Tele-Book or Tele-Professional) (11) only in the mode: MultiMaster-Mode (12) up to a maximum baud rate of 187.5 KBit/s (13) In this transmission, the baud rate is irrelevant, because it communicates via a virtual COM-port. (14) with the use of the TS-adapter / item number: 9350.TS (15) Update directly with PC and TIC-driver (18) Operation requires Step 7 with additional software Tele-Service (TS) from Siemens (19) only at PPI-communication possible (20) Only with TIC-driver (21) with integrated webserver possible (22) No support of Siemens Step7-software possible (23) Only with USB and with TIC-driver |
S7-PLC over LAN
Communication with S7-PLC via Ethernet, just how and with what?
Data-communication with S7-PLC from PC or other devices via network, which interface is required. Questions you don't
have to worry about. With "S7 over LAN" you get the right interface-products for PPI, MPI and Profibus.
Which one you use then is up to you.
All prices plus costs of delivery, shipping insurance and VAT.
All prices plus costs of delivery, shipping insurance and VAT.
S7
USB
S7-PLC-communication (PPI, MPI + DP) via USB-port
S7-PLC-communication (PPI, MPI + DP) via USB-port
WLAN/WIFI
S7-PLC-communication (PPI, MPI + DP) via WIFI
S7-PLC-communication (PPI, MPI + DP) via WIFI
RS232
S7-PLC-communication (PPI, MPI + DP) via COM-port
S7-PLC-communication (PPI, MPI + DP) via COM-port
All prices plus costs of delivery, shipping insurance and VAT.
Automatic-mode
Main downloads
Versionstory
Documentation
- Short instruction MPI-LAN
- Short instruction S7-BRIDGE
- Short instruction S7-GATE
- Short instruction S7-LAN
- Short instruction S7-LAN++
- Example PUT/GET for Simatic-Manager and TIA-portal
- Examples of S5-/S7-coupling (S5-PLC and/or S7-PLC active)
- Handbook S7-LAN/S7-GATE/MPI-LAN/S7-USB/MPI-USB/MPI-II
- Information-sheet S7-LAN
- Handbook S5-/S7-BRIDGE
- Short instruction S7-interface (german only)
- Short instruction S7-LAN
- Example of use: Watchdog-option
- Handbook MPI-LAN (older version)
- Handbook S7-LAN (older version)