Server machine-data OPC-DA (Classic-OPC)
Data exchange between OPC-Clients and PLC’s
singlelicense
+ S7-TCP/IP
+ OPC S7 MPI/PPI
+ OPC S7 PPI S7-200
+ OPC S5 AS511 serial
+ OPC S5 H1 on TCP
- S5-LAN++
- S7-LAN
- MPI-LAN
- MPI-II-Kabel
- MPI-USB
- S7-USB
- MPI/PPI
more...
ARTNR: 9760-100
Server machine-data OPC-DA S7 TCP/IP RFC1006
EAN number: | 4260363240611 | |
HS-code: | 85234990 |
Alternativen
Server machine-data OPC-DA S7 TCP/IP RFC1006
singlelicense + S7-TCP/IP + OPC S7 MPI/PPI + OPC S7 PPI S7-200 + OPC S5 AS511 serial + OPC S5 H1 on TCP
plus VAT. and shipping
Server machine-data OPC-DA lite
singlelicense free license (maximum 100 items) for: S5-LAN++ S7-LAN / MPI-LAN-cable MPI/PPI-cable MPI-II-cable MPI-USB-cable S7-USB
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
Server mach.-data OPC-DA Klöckner Moeller PS4/PS416
singlelicense serial comunication over COM-port
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
- S5-LAN++
- S7-LAN
- MPI-LAN
- MPI-II-Kabel
- MPI-USB
- S7-USB
- MPI/PPI
Please request the license with the serial-number of the respective product.
Features:
- Unlimited number of connections
- Per Server machine-data OPC-DA session can be coupled to any number of different control protocols. There is no need to start and configure different sessions.
- Unlimited number of items
Likewise, the number of coupled items is unlimited and not tied to maturity. - Manual creation of items
In addition to the automatic creation of items by OPC-clients, the Server machine-data OPC-DA also supports manual creation. Thus, the connection of an item in text form is done directly in the item-table or by import of symbol-tables. The format adaptation allows a type-specific processing. - Actual- and set-values representation of items
Parameterized items can be viewed online in the Server machine-data OPC-DA. There, the actual- and set-values as well as their respective time stamp are displayed.
- Communication-recording of the coupled modules in real-time
- Simulation whenever you want
Each configured controller can be switched to simulation mode, so that the external control can be dispensed with as real hardware. Since our visualization Victory, the visual factory accesses the same communication-drivers as the Server machine-data OPC-DA, can this even be used as an intelligent simulation environment. - Four serial ports (COM1 – COM4)
- Low CPU stress
- For Windows (any)
- License is licensed on PC-hardware.
USB-dongle is an alternative, because wherever the dongle is plugged the license is running.
The following protocols are currently supported:
- S7 TCP/IP (RFC1006, CP343-1, CP443-1, S7-LAN, MPI-LAN)
- S7 MPI / PPI (MPI/PPI-Kabel, MPI-II, MPI-USB, S7-USB)
- S5 TCP/IP – H1 (RFC1006, CP143-TCP, S5-LAN++, VIPA-CP)
- S5 AS512 (RK511)
- S5 3964R (RK512)
- Moeller PS4/PS416
- AEG A120/A250 (KS-functions)
- Modbus RTU/ASCII serial, TCP/IP, remote data transmission
- IBH softec SoftPLC
- WAGO Ethernet TCP/IP FPC
- SAIA PLC (S-Comm)
Notice to the user:
The "Visual C++ Redistributable Package" is required for the "entry as a service" of the application in Windows-operating-systems Windows XP SP3, Vista, 7, 8, 8.1, 10 as well as Server 2003, 2008 and 2012.
If it is not already part of your Windows-installation, you can install it at any time.
The 32-bit package (vc_redist.x86.exe) is sufficient for this tool even with 64-bit operating-systems:
Download
Machines from various manufacturers in the production-plant and with all of them should data be exchanged?
Before you get the machine-specific protocol from each manufacturer in order to integrate it into your application,
there are easier ways to implement this requirement.
OPC-servers have many protocols from different manufacturers integrated and provide the collected data as
"Server". Your application communicates as a "client" with the OPC-protocol DA (Classic) with the
"Server" and thus receives the required data from all machines without knowing the respective protocol.
Access with one protocol and still have data from many manufacturers, that is OPC.
options:
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
Server mach.-data OPC-DA Klöckner Moeller PS4/PS416
singlelicense serial comunication over COM-port
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
accessories:
plus VAT. and shipping
Server machine-data OPC-DA S7 TCP/IP RFC1006
singlelicense + S7-TCP/IP + OPC S7 MPI/PPI + OPC S7 PPI S7-200 + OPC S5 AS511 serial + OPC S5 H1 on TCP
plus VAT. and shipping
Server machine-data OPC-DA lite
singlelicense free license (maximum 100 items) for: S5-LAN++ S7-LAN / MPI-LAN-cable MPI/PPI-cable MPI-II-cable MPI-USB-cable S7-USB
plus VAT. and shipping
plus VAT. and shipping
OPC-Server
Easy UA-server
Framework Advanced
Universal - simple - contemporary - expandable platform
plus VAT. and shipping
S7-LAN connector for Siemens S7 PLC controller Obsolete
Successor: S7-LAN++ connector for Siemens S7 Controller (Art.No: 9352-LANCON++)
Network-connection for the S7-200/300/400-PLC +++ S7-adapter PPI/MPI/PROFIBUS +++ Of developer and manufacturer +++ Smallest Ethernet-gateway S7 +++ Network for each S7-PLC +++ Fast commissioning +++ Replacement for CP343-1/443-1
plus VAT. and shipping
plus VAT. and shipping
Server machine-data OPC-UA
singlelicense windows (any) Only UA-server, no mobile HMI included
plus VAT. and shipping
S5-LAN++
Industrial Ethernet <> S5 PD-interface (TTY) Including Gateway Plus and S7-TCP / IP functions
plus VAT. and shipping