PLC-data logging/triggering
Automated writing of data from the PLC to a file
singlelicense
windows (any) (from .Net 3.5)
PLC-Datalogger
Log/archive production data in CSV file/XML file
With "PLC-data logging/triggering" process and production data of any number of SIMATIC S7 can be quickly and easily recorded and logged. The S7 models S7-1500, S7-1200, S7-300 / 400, LOGO !, WIN AC RTX and S5 are supported via S5-LAN ++.
With minimal configuration effort directly for logging.
Using the trigger, the logging can be controlled depending on the time or by events in the PLC. The process data is structured, recorded as a stack or as a ring buffer and saved as CSV or XML. The target directory and the file name
more...
ARTNR: 9771-S7L
PLC-data logging/triggering TCP/IP S7 - Standard
EAN number: | 4260363245814 | |
HS-code: | 85234990 |
Alternativen
PLC-data logging/triggering TCP/IP S7 - Standard
singlelicense windows (any) (from .Net 3.5)
plus VAT. and shipping
PLC-data logging/triggering TCP/IP S7 - Advanced
Singlelicense windows (any) (from .Net 3.5)
plus VAT. and shipping
PLC-data logging/triggering TCP/IP S7 - Expert
singlelicense windows (any) (from .Net 3.5)
plus VAT. and shipping
PLC-data logging/triggering TCP/IP S7 - Standard
subsequentlicense windows (any) (from .Net 3.5)
plus VAT. and shipping
PLC-data logging/triggering TCP/IP S7 - Advanced
subsequentlicense windows (any) (from .Net 3.5)
plus VAT. and shipping
PLC-data logging/triggering TCP/IP S7 - Expert
subsequentlicense windows (any) (from .Net 3.5)
plus VAT. and shipping
PLC-data logging/triggering TCP/IP S7 - Standard
Site / Branch / Standort License windows (any) (from .Net 3.5)
plus VAT. and shipping
PLC-data logging/triggering TCP/IP S7 - Advanced
Site / Branch / Standort License windows (any) (from .Net 3.5)
plus VAT. and shipping
PLC-data logging/triggering TCP/IP S7 - Expert
Site / Branch / Standort License windows (any) (from .Net 3.5)
plus VAT. and shipping
Software Update & Support service
Automatical Upgrade for innovations incl. technical support for 12 months for a single-license standard Requirements: single-license PLC-data logging/triggering- standard-version not older than 9 months or together with PLC-data logging/triggering.
plus VAT. and shipping
Software Update & Support service dongle-version
Automatical Upgrade for innovations incl. technical support for 12 months for a single-license expert Requirements: single-license PLC-data logging/triggering- expert-version not older than 9 months or together with PLC-data logging/triggering with dongle-license
plus VAT. and shipping
Software Update & Support service dongle-version
Automatical Upgrade for innovations incl. technical support for 12 months for a single-license standard Requirements: single-license PLC-data logging/triggering- standard-version not older than 9 months or together with PLC-data logging/triggering with dongle-license
plus VAT. and shipping
Software Update & Support service
Automatical Upgrade for innovations incl. technical support for 12 months for a Site / Branch / Standort License expert Requirements: Site / Branch / Standort License PLC-data logging/triggering-expert-version not older than 9 months or together with PLC-data logging/triggering.
plus VAT. and shipping
Software Update & Support service
Automatical Upgrade for innovations incl. technical support for 12 months for a subsequent-license expert Requirements: subsequent-license PLC-data logging/triggering- expert-version not older than 9 months or together with PLC-data logging/triggering.
plus VAT. and shipping
Software Update & Support service
Automatical Upgrade for innovations incl. technical support for 12 months for a single-license expert Requirements: single-license PLC-data logging/triggering- expert-version not older than 9 months or together with PLC-data logging/triggering.
plus VAT. and shipping
Software Update & Support service
Automatical Upgrade for innovations incl. technical support for 12 months for a Site / Branch / Standort License advanced Requirements: Site / Branch / Standort License PLC-data logging/triggering-advanced-version not older than 9 months or together with PLC-data logging/triggering.
plus VAT. and shipping
Software Update & Support service
Automatical Upgrade for innovations incl. technical support for 12 months for a subsequent-license advanced Requirements: subsequent-license PLC-data logging/triggering- advanced-version not older than 9 months or together with PLC-data logging/triggering.
plus VAT. and shipping
Software Update & Support service
Automatical Upgrade for innovations incl. technical support for 12 months for a single-license advanced Requirements: single-license PLC-data logging/triggering- advanced-version not older than 9 months or together with PLC-data logging/triggering.
plus VAT. and shipping
Software Update & Support service
Automatical Upgrade for innovations incl. technical support for 12 months for a Site / Branch / Standort License Standard Requirements: Site / Branch / Standort License PLC-data logging/triggering-standard-version not older than 9 months or together with PLC-data logging/triggering.
plus VAT. and shipping
Software Update & Support service
Automatical Upgrade for innovations incl. technical support for 12 months for a subsequent-license standard Requirements: subsequent-license PLC-data logging/triggering- standard-version not older than 9 months or together with PLC-data logging/triggering.
plus VAT. and shipping
Software Update & Support service dongle-version
Automatical Upgrade for innovations incl. technical support for 12 months for a single-license advanced Requirements: single-license PLC-data logging/triggering- advanced-version not older than 9 months or together with PLC-data logging/triggering with Dongle-license
plus VAT. and shipping
PLC-data logging/triggering license-dongle AddOn
USB-dongle with license-key instead of software-key windows (any) from Win7
plus VAT. and shipping
PLC-Datalogger
Log/archive production data in CSV file/XML file
With "PLC-data logging/triggering" process and production data of any number of
SIMATIC S7 can be quickly and easily recorded and logged. The S7 models S7-1500,
S7-1200, S7-300 / 400, LOGO !, WIN AC RTX and S5 are supported via S5-LAN ++.
With minimal configuration effort directly for logging.
Using the trigger, the logging can be controlled depending on the time or by
events in the PLC. The process data is structured, recorded as a stack or as
a ring buffer and saved as CSV or XML. The target directory and the file name
can be created dynamically with date and time stamps. The application can run
as a service.
The program can be run on all Windows 32/64 bit (windows (any)).
- Free evaluation without registration
- Simple and fast logging
- Industrial reliability
- Qualified support
- Comprehensive documentation
- Create snapshots of SIMATIC S7 process data
- Saving production data
- Data-logging without PLC-program
- Data-logging controlled by the PLC
- Cycle-accurate recording for system-failure analysis
- Archive production data
- Save recipes
The connection to the S7 is made via the S7-TCP/IP-protocol.
No programming is required in the PLC.
Supports all S7 data-types from Bool to DateTime and String etc.
Supported operating systems:
- Windows (any)
Min. Pentium III 1.200 MHz, 1 GB RAM, ca. 40 MB for software and enough space for the logger files
Supported PLC types:
- S7-1500
- S7-1200
- S7-300/400
- Win AC RTX
- S7-200
- LOGO!
- S7-kompatible SPS (z. Bsp.: VIPA, Saia, Berthel)
- S5 über S5-LAN++
- S7-LAN
- 4 trigger types for logging
from interval to value change, from edges to user-defined conditions - Data from up to 256 SIMATIC S7 controllers
can be monitored and logged at the same time - Siemens controls like
SIMATIC LOGO! / SIMATIC S7-200 / SIMATIC S7-300 / SIMATIC S7-400 / SIMATIC S7-1200 / SIMATIC S7-1500 / S7-compatible PLC (for e.g.: VIPA, Saia, Berthel) / S5 (over S5-LAN++) / S7-LAN - Reading and logging of
inputs, outputs, flags, data-blocks, timers and counters - Execution of logging
via the command-line, as a service or directly in the application - Addressing "organized data" as
variables in stacks and ring-buffers - Reading device information such as
Location, module identifier, module series, DB-sizes and system-time - PDU-optimized access for
high-performance acquisition of consistent data - Abort detection for backup of
constant connections through automatic reconnection - Addressing of all data-areas with
identifiers in the format of the SIEMENS and IEC-syntax - Boolean values and numeric values of
1 to 8, 16, 32 and 64 bit data length – also as ARRAY OF - Signed and unsigned integer values above
BYTE, WORD, DWORD, INT and DINT – also as ARRAY OF - Single/double precision floating point values
REAL and DOUBLE – also as ARRAY OF - Date and time values about
TIME, S5-TIME, DATE and DATE_AND_TIME - Character and character-strings above
CHAR to S7-STRING – also via BYTE with its own encoding - Structured data
with static and dynamic addressing
Features
|
Standard
|
Advanced
|
Expert
|
Evaluation
[Demo] |
Trigger based log-file creation |
|
x
|
x
|
x
|
Stack Logging |
|
x
|
x
|
x
|
Ring-buffer logging |
|
|
x
|
x
|
Command line logging |
|
x
|
x
|
x
|
Logging as a service |
x
|
x
|
x
|
x
|
Maximum number of channels |
4
|
16
|
256
|
256
|
Maximum number of shown records |
500
|
500
|
500
|
100
|
Maximum number of records each event |
1
|
32767
|
32767
|
1
|
Maximum number of triggers |
2
|
4
|
8
|
8
|
Interval trigger |
x
|
x
|
x
|
x
|
Boolean trigger |
|
x
|
x
|
x
|
Conditional/edge trigger |
|
x
|
x
|
x
|
Maximum number of variables |
100
|
500
|
1000
|
1000
|
Log to CSV |
x
|
x
|
x
|
x
|
Log to XML |
|
x
|
x
|
x
|
Destination directory selectable |
x
|
x
|
x
|
x
|
Add date/time to file-name and directory |
x
|
x
|
x
|
x
|
Trigger time-grid 100ms - days |
x
|
x
|
x
|
x
|
Fixed number of data records can be buffered in PLC |
|
x
|
x
|
x
|
Real-time recording by FIFO in the PLC |
|
x
|
x
|
|
Start/stop recording by PLC |
|
x
|
x
|
License | |
Single License | Installation on one workstation/PC |
Subsequent License | Installation on an additional workstation/PC one subsequentlicense for each additional workstation/PC Requirement: 1x singlelicense |
Site / Branch / Standort License | unlimited number of installations at one location (= one postal address) of a company |
Support/Updates:
A license is purchased once for a specific installation or as a dongle and is valid indefinitely (= unlimited license lifetime). In addition, our top-level support from our developers as well as updates including new functions can be purchased for 12 months.
Shortly before the support expires, it is possible to extend it for at least another 12 months for 10% of the current list-price. Updates (= current demo-version) and new functions can only be obtained with valid support. Support requests can still be made, but depending on the scope, these will be dealt with later.
Up to one month before the end of active support, we will inform you about the possibility of extending support. A support renewal is possible at any time in the first year after the end of support for 10% + 20% for each started quarter (since the end of support) of the current list-price. After the first year, a new license must be purchased for the support renewal.
Differences between"PLC-data logging/triggering" and "PLC-data in Excel" (Find the right product for your requirements):
Features
|
PLC-data logging/triggering
|
PLC-data in Excel
|
What happens in the event of a trigger event |
Defined values are appended in a given file with a time stamp
one file for several trigger events (infinite list) |
The specified file is filled with values from the controller and saved as a new file
one Excel file per trigger event |
Filename |
Specified by the configuration of the tool
|
Can be specified by the PLC, otherwise by the tool
|
Number of configured S7 connections |
Depending on the license from 4 to 256
|
1 connection
|
Number of variables/connection |
Depending on the license from 100 to 1000
|
Depending on the license from 100 to unlimited
|
Licensing process:
Free download of the complete range of functions
for 14 days:
/sps-daten-loggentriggern.html/
Licensing under "License"
(mouse click on the key symbol)
Your machine-code for this PC with order by email
to verkauf@process-informatik.de
You will receive a license code to enter under
"License", so that the program is licensed on your
PC.
With a USB-dongle, there is no machine-code, the
USB-dongle contains the license, comes via UPS.
Save your PLC content, production-data in a file on your PC. This file, a CSV- or XML-file (depending
on the license), can then be used e.g. further processed with Excel.
A file that includes all configured variables in an infinitely-long list with a suitable time-stamp,
either controlled by the PC or via a PLC-trigger (depending on the license). No matter which
Siemens-control, as soon as a network-connection is available, nothing stands in the way of recording.
With S7-LAN for PPI, MPI or Profibus or S5-LAN++ for S5-controllers, PLCs without a network-connection
can also be addressed and recorded. And depending on the license are several parallel connections possible.
support-service:
Software Update & Support service
Automatical Upgrade for innovations incl. technical support for 12 months for a single-license standard Requirements: single-license PLC-data logging/triggering- standard-version not older than 9 months or together with PLC-data logging/triggering.
plus VAT. and shipping
Software Update & Support service dongle-version
Automatical Upgrade for innovations incl. technical support for 12 months for a single-license expert Requirements: single-license PLC-data logging/triggering- expert-version not older than 9 months or together with PLC-data logging/triggering with dongle-license
plus VAT. and shipping
Software Update & Support service dongle-version
Automatical Upgrade for innovations incl. technical support for 12 months for a single-license standard Requirements: single-license PLC-data logging/triggering- standard-version not older than 9 months or together with PLC-data logging/triggering with dongle-license
plus VAT. and shipping
Software Update & Support service
Automatical Upgrade for innovations incl. technical support for 12 months for a Site / Branch / Standort License expert Requirements: Site / Branch / Standort License PLC-data logging/triggering-expert-version not older than 9 months or together with PLC-data logging/triggering.
plus VAT. and shipping
Software Update & Support service
Automatical Upgrade for innovations incl. technical support for 12 months for a subsequent-license expert Requirements: subsequent-license PLC-data logging/triggering- expert-version not older than 9 months or together with PLC-data logging/triggering.
plus VAT. and shipping
Software Update & Support service
Automatical Upgrade for innovations incl. technical support for 12 months for a single-license expert Requirements: single-license PLC-data logging/triggering- expert-version not older than 9 months or together with PLC-data logging/triggering.
plus VAT. and shipping
Software Update & Support service
Automatical Upgrade for innovations incl. technical support for 12 months for a Site / Branch / Standort License advanced Requirements: Site / Branch / Standort License PLC-data logging/triggering-advanced-version not older than 9 months or together with PLC-data logging/triggering.
plus VAT. and shipping
Software Update & Support service
Automatical Upgrade for innovations incl. technical support for 12 months for a subsequent-license advanced Requirements: subsequent-license PLC-data logging/triggering- advanced-version not older than 9 months or together with PLC-data logging/triggering.
plus VAT. and shipping
Software Update & Support service
Automatical Upgrade for innovations incl. technical support for 12 months for a single-license advanced Requirements: single-license PLC-data logging/triggering- advanced-version not older than 9 months or together with PLC-data logging/triggering.
plus VAT. and shipping
Software Update & Support service
Automatical Upgrade for innovations incl. technical support for 12 months for a Site / Branch / Standort License Standard Requirements: Site / Branch / Standort License PLC-data logging/triggering-standard-version not older than 9 months or together with PLC-data logging/triggering.
plus VAT. and shipping
Software Update & Support service
Automatical Upgrade for innovations incl. technical support for 12 months for a subsequent-license standard Requirements: subsequent-license PLC-data logging/triggering- standard-version not older than 9 months or together with PLC-data logging/triggering.
plus VAT. and shipping
Software Update & Support service dongle-version
Automatical Upgrade for innovations incl. technical support for 12 months for a single-license advanced Requirements: single-license PLC-data logging/triggering- advanced-version not older than 9 months or together with PLC-data logging/triggering with Dongle-license
plus VAT. and shipping
accessories:
PLC-data logging/triggering license-dongle AddOn
USB-dongle with license-key instead of software-key windows (any) from Win7
plus VAT. and shipping
Einzel-Lizenz
PLC-data logging/triggering TCP/IP S7 - Standard
singlelicense windows (any) (from .Net 3.5)
plus VAT. and shipping
PLC-data logging/triggering TCP/IP S7 - Advanced
Singlelicense windows (any) (from .Net 3.5)
plus VAT. and shipping
PLC-data logging/triggering TCP/IP S7 - Expert
singlelicense windows (any) (from .Net 3.5)
plus VAT. and shipping
Folge-Lizenz
PLC-data logging/triggering TCP/IP S7 - Standard
subsequentlicense windows (any) (from .Net 3.5)
plus VAT. and shipping
PLC-data logging/triggering TCP/IP S7 - Advanced
subsequentlicense windows (any) (from .Net 3.5)
plus VAT. and shipping
PLC-data logging/triggering TCP/IP S7 - Expert
subsequentlicense windows (any) (from .Net 3.5)
plus VAT. and shipping
Standort-Lizenz
PLC-data logging/triggering TCP/IP S7 - Standard
Site / Branch / Standort License windows (any) (from .Net 3.5)
plus VAT. and shipping
PLC-data logging/triggering TCP/IP S7 - Advanced
Site / Branch / Standort License windows (any) (from .Net 3.5)
plus VAT. and shipping
PLC-data logging/triggering TCP/IP S7 - Expert
Site / Branch / Standort License windows (any) (from .Net 3.5)
plus VAT. and shipping
Software Update & Support service
Automatical Upgrade for innovations incl. technical support for 12 months for a single-license standard Requirements: single-license PLC-data logging/triggering- standard-version not older than 9 months or together with PLC-data logging/triggering.
plus VAT. and shipping
PLC-data logging/triggering license-dongle AddOn
USB-dongle with license-key instead of software-key windows (any) from Win7
plus VAT. and shipping
S7-LAN connector for Siemens S7 PLC controller Obsolete
Successor: S7-LAN++ connector for Siemens S7 Controller (Art.No: 9352-LANCON++)
Network-connection for the S7-200/300/400-PLC +++ S7-adapter PPI/MPI/PROFIBUS +++ Of developer and manufacturer +++ Smallest Ethernet-gateway S7 +++ Network for each S7-PLC +++ Fast commissioning +++ Replacement for CP343-1/443-1
plus VAT. and shipping
PLC-data in Excel license-dongle AddOn
USB-dongle with license-key instead of software-key windows (any) from Win7
plus VAT. and shipping
PLC-data logging/triggering TCP/IP S7 - Advanced
Singlelicense windows (any) (from .Net 3.5)
plus VAT. and shipping
Software Update & Support service
Automatical Upgrade for innovations incl. technical support for 12 months for a single-license advanced Requirements: single-license PLC-data logging/triggering- advanced-version not older than 9 months or together with PLC-data logging/triggering.
plus VAT. and shipping