Cookies helfen uns bei der Bereitstellung unserer Dienste. Durch die Nutzung unserer Dienste erklären Sie sich damit einverstanden, dass wir Cookies setzen.
Cookies help us in providing our services. By using our services, you agree that we set cookies.
OK
Data-backup S7-PLC PN-port on USB-Stick - Process Informatik Entwicklungsgesellschaft mbH

Data-backup S7-PLC PN-port on USB-Stick Download


S7 PLC data Hardware-independent safe/restore directly to/from the USB-STICK universally with PLC-Trigger!

Operating as a client or access-point
Configuration via web-server
Supply: 24V DC

Product Overview:

SPS data backup without installation of additional software on each USB-STICK, SD-CARD and every FTP server.
Machine data is simply and reliably deducted from Siemens S7 PLC controllers and stored on any FTP server.
No matter if daily data backup , storage processes, machine change or after every production cycle .
Writes all production relevant data to your server for archiving and further processing.
Thanks to the integrated reverse play function , saved data can be transferred back to the PLC machine at any time. Ideal also in test trials and control conversions.

Highlights:

  • Thanks to the USB stick as a storage medium, you can back up machine data in the shortest possible time and transport it to other machines as required.
  • When delivering the same machine again, customers can bring their data directly for acceptance, no PLC knowledge required! Insert the USB stick and set the PLC trigger!


    more...
    264,00 € plus VAT. and shipping

    ARTNR: 9201
    EtherSens Basic
    EAN number: 4260363244282
    HS-code: 85423190
    Weight: 0.3 kg



    Product Overview:

    SPS data backup without installation of additional software on each USB-STICK, SD-CARD and every FTP server.
    Machine data is simply and reliably deducted from Siemens S7 PLC controllers and stored on any FTP server.
    No matter if daily data backup , storage processes, machine change or after every production cycle .
    Writes all production relevant data to your server for archiving and further processing.
    Thanks to the integrated reverse play function , saved data can be transferred back to the PLC machine at any time. Ideal also in test trials and control conversions.

    Highlights:

    • Thanks to the USB stick as a storage medium, you can back up machine data in the shortest possible time and transport it to other machines as required.
    • When delivering the same machine again, customers can bring their data directly for acceptance, no PLC knowledge required! Insert the USB stick and set the PLC trigger!

    • Triggering directly out of the S7 controler , thus no time lag and delays due to external circuits or regulator.
    • No change at your Simatic S7 controller.
    • Data can also be processed directly from the device by external controllers such as S7-1200 / S7-1500 or with CPs.
    • Bidirectional Backup & Playback!

    ! DOUBLE FUNCTIONS for PLC experts!

    • ALARM_MESSAGE DISPATCH INTEGRATED

      • Freely selectable fault annunciator integrated, not only in case of faulty recording, no, a directly operation monitor for your production plant .
      • Resets any error messages send by mail to any number of recipients.
      • As a result, no plant supervisor escapes a malfunction!
      • Avoid high costs caused by machine downtime!

    Application areas:

    -
    Save data on your FTP data base , like production data and all relevant system parameters.
    - Use a simple
    USB-STICK, SD-CARD or a FTP server as data backup server , no extra software necessary.
    - Backups before
    System conversions / changes !
    - Save freely selectable DB contents and restore them!
    - Link S7-Siemens PLC to any TCP/IP devices and get access to the process data directly.
    - Schedule-relevant data, e.g. after finished palletizing
    PLC trigger controlled storing.

    Configuration:

    The configuration takes place directly into the
    integrated web server .
    Thanks to the designed flash memory, data can not be lost, which means a device can be easily tested at the office and then sent to the construction site__.
    Even in the event of power failure or other supply disruptions
    there is no danger to the data.
    After configuration
    no additional PC is required **. The installation is self-explanatory and can be carried out on-site by untrained personnel.
    Data backup S5-PLC on FTP-Server
    Produkbild

    S5-PLC triggered DB-backup/-restore without additional PC via PG-socket and Ethernet on FTP-server

    Data backup S5-PLC on FTP-server via dig. IO
    Produkbild

    Via digital input triggered DB-backup/-restore without additional PC via PG-socket and Ethernet to FTP-server

    Data backup S5-PLC on SD-card
    Produkbild

    S5-PLC triggered DB-backup/-restore without additional PC via PG-socket and Ethernet on SD-card

    Data backup S5-PLC on SD-card via dig. IO
    Produkbild

    Via digital input triggered DB-backup/-restore without additional PC via PG-socket and Ethernet to SD-card

    Data backup S5-PLC on USB-stick
    Produkbild

    S5-PLC triggered DB-backup/-restore without additional PC via PG-socket and Ethernet on USB-stick

    Data backup S5-PLC on USB-stick via dig. IO
    Produkbild

    Via digital input triggered DB-backup/-restore without additional PC via PG-socket and Ethernet to USB-stick

    Data backup S7-PLC PN-port on FTP-server
    Produkbild

    S7-PLC triggered DB-backup/-restore without additional PC via PN-port on FTP-server

    Data backup S7-PLC PN-port on FTP-server via dig. IO
    Produkbild

    Via digital input triggered DB-backup/-restore without additional PC via PN-port to FTP-server

    Data backup S7-PLC PN-port on SD-card
    Produkbild

    S7-PLC triggered DB-backup/-restore without additional PC via PN-port on SD card

    Data backup S7-PLC PN-port on SD-card via dig. IO
    Produkbild

    Via digital input triggered DB-backup/-restore without additional PC via PN-port to SD-card

    Data backup S7-PLC PN-port on USB-stick
    Produkbild

    S7-PLC triggered DB-backup/-restore without additional PC via PN-port to USB-stick

    DB-Backup/Restore S7-PLC PN-port on USB-stick via dig. IO
    Produkbild

    Via digital input triggered DB-backup/-restore without additional PC via PN-port to USB-stick

    Data backup S7-PLC over MPI/Profibus on FTP-server
    Produkbild

    S7-PLC triggered DB-backup/-restore without additional PC via MPI/Profibus on FTP-server

    Data backup S7-PLC over MPI/Profibus on FTP-server via dig. IO
    Produkbild

    Via digital input triggered DB-backup/-restore without additional PC via MPI/Profibus to FTP-server

    Data backup S7-PLC over MPI/Profibus on SD-card
    Produkbild

    S7-PLC triggered DB-backup/-restore without additional PC via MPI/Profibus on SD-card

    Data backup S7-PLC over MPI/Profibus on SD-card via dig. IO
    Produkbild

    Via digital input triggered DB-backup/-restore without additional PC via MPI/Profibus to SD-card

    Data backup S7-PLC over MPI/Profibus on USB-stick
    Produkbild

    S7-PLC triggered DB-backup/-restore without additional PC via MPI/Profibus on USB-stick

    Data backup S7-PLC over MPI/Profibus on USB-stick via dig. IO
    Produkbild

    Via digital input triggered DB-backup/-restore without additional PC via MPI/Profibus to USB-stick

    Message dispatch from the PLC
    Produkbild

    Send directly from your PLC news, statuses, alarms as SMS or email.

    Supply voltage: 24V DC +/- 20%
    Power consumption: 2 watt
    Display: WEB-Browser
    1 status LED bicolor
    Handling/Configuration: WEB-Browser
    Interfaces: Slot for microSD
    Antenna-connector SMA(f) (2.4 GHz IEEE 802.11b/g)
    10/100BaseTX RJ45-ethernet-plug
    Button for factory settings
    Overvoltage category: CAT IV
    Insulation value
    network <=> mains voltage:
    1,5 KV
    Operating temperature: 0 - 55°C
    Case: ABS-plastic case V0
    Dimensions: 100 x 112 x 45 mm
     
    Scope of delivery: EtherSens Basic
    WIFI-stub-antenna
    All prices plus costs of delivery, shipping insurance and VAT.

    extensions:

    9230-AIO
    Extension Analog-IO V1.0

    Extension-board for EtherSens-devices 4 x analog IN 0-5V opt. with ext.Shunt 0/4-20mA opt. with ext. restistance 0-10/24/50V 4 x analog OUT 0/4-20mA (24V) Power consumption: 4W
    Quickbestellung INFOMAIL
    by e-mail
    128,00 €
    plus VAT. and shipping


    9230-EI2C-5V
    Extension with ext. galv. separated I2C 5V

    Extension-board for EtherSens-devices with galvanic separated external I2C-connector for 5V Power consumption: 2W
    Quickbestellung INFOMAIL
    by e-mail
    117,00 €
    plus VAT. and shipping


    9230-LTE
    Extension LTE-modem

    LTE-modem-board for EtherSens-devices Send/receive of SMS-messages Communication from/into internet Power consumption: 6,5W
    Quickbestellung INFOMAIL
    by e-mail
    264,00 €
    plus VAT. and shipping


    9230-ENERGY
    Extension Energy-IO

    Extension-board for EtherSens-devices Energy-analysis (EN 50470-1 EN 50470-3) L1, L2, L3, N realtime analysis Up to 8000 measurements / second Hz / cos phi / power-factor Energy consumption kWh For Rogwski-coils up to 0,5V
    Quickbestellung INFOMAIL
    by e-mail
    352,00 €
    plus VAT. and shipping


    9220-U-I-BOX
    U-I-box for EtherSens

    max. 1000V DC / 40A 24V DC supply 20cm power-cable 4mm2 with Amphenol-plug I2C-connection 1m
    Quickbestellung INFOMAIL
    by e-mail
    158,00 €
    plus VAT. and shipping


    9220-SONNE
    Sun-light-sensor for EtherSens

    max. 220k Lux (switchable ranges) 3.3V DC supply (from I2C-interfaceport) I2C-connection 1m
    Quickbestellung INFOMAIL
    by e-mail
    105,00 €
    plus VAT. and shipping


    9220-GYRO-SENS-312
    Gyro-Sensor 312 for EtherSens
    Measuring range: ±1.5g / ±3g / ±6g / ±12g 3.3V DC supply (from I2C-interfaceport) I2C-connection 1m
    Quickbestellung INFOMAIL
    by e-mail
    105,00 €
    plus VAT. and shipping


    9220-GYRO-SENS-313
    Gyro-Sensor 313 for EtherSens
    Measuring range: ±0.5g / ±1g / ±2g / ±4g 3.3V DC supply (from I2C-interfaceport) I2C-connection 1m
    Quickbestellung INFOMAIL
    by e-mail
    105,00 €
    plus VAT. and shipping


    9220-T-LF-D
    Temp./humidity/air-pressure for EtherSens

    Measuring range: Temperature: -40 ...+85°C Humidity: 0...100% relative Feuchte Pressure: 300...1100 hPa 3.3V DC supply (from I2C-interfaceport) I2C-connection 1m
    Quickbestellung INFOMAIL
    by e-mail
    105,00 €
    plus VAT. and shipping


    9220-SEG-ANZEIGE
    Segment-display for EtherSens
    4 Digit 14 segment-display WHITE 0,56" high in wall-mounting case 5V DC supply (from I2C-interfaceport) I2C-connection
    Quickbestellung INFOMAIL
    by e-mail
    158,00 €
    plus VAT. and shipping


    9230-EI2C-3.3V
    Extension with ext. galv. separated I2C 3.3V

    Extension-board for EtherSens-devices with galvanic separated external I2C-connector for 3.3V Power consumption: 2W
    Quickbestellung INFOMAIL
    by e-mail
    117,00 €
    plus VAT. and shipping


    9230-MIO-485
    Extension RS485-IO

    Extensionboard for EtherSens-devices V1.0 for RS485 Power consumption: 2W
    Quickbestellung INFOMAIL
    by e-mail
    158,00 €
    plus VAT. and shipping


    9230-MIO-TTY
    Extension TTY-IO

    Extensionboard for EtherSens-devices V1.0 for TTY (incl. 2x current-sources) Power consumption: 2W
    Quickbestellung INFOMAIL
    by e-mail
    158,00 €
    plus VAT. and shipping


    9230-DIO
    Extension Digital-IO

    Extension-board for EtherSens-devices 12 x digital IN or OUT 24VDC 400mA free config with software Power consumption: 4W
    Quickbestellung INFOMAIL
    by e-mail
    191,00 €
    plus VAT. and shipping


    9230-GG
    Bigger Case
    Width 90mm instead of 45mm
    Quickbestellung INFOMAIL
    by e-mail
    106,00 €
    plus VAT. and shipping


    9230-RIO-24V
    Extension 24V Relay-IO

    Extension-board for EtherSens-devices Supply voltage: 24V DC 4 x relay-OUT 230VAC/16A Power consumption: 4W
    Quickbestellung INFOMAIL
    by e-mail
    170,00 €
    plus VAT. and shipping


    9230-RIO-230V
    Extension 230V Relay-IO

    Extension-board for EtherSens-devices Supply voltage: 230V AC 4 x relay-OUT 230VAC/16A Power consumption: 2,5W
    Quickbestellung INFOMAIL
    by e-mail
    227,00 €
    plus VAT. and shipping


    9230-NT-230V
    Power-supply-rack-unit 230V

    Input voltage: 100 - 240VAC 50-60Hz Output voltage: 24V DC Power: 4W
    Quickbestellung INFOMAIL
    by e-mail
    68,00 €
    plus VAT. and shipping


    9230-AIO-V1.1
    Extension Analog-IO V1.1

    Extension-board for EtherSens-devices 4 x Analogue Input (switchable between U, I, differential) 4 x analog OUT 0/4-20mA (24V) Power consumption: 4W
    Quickbestellung INFOMAIL
    by e-mail
    149,00 €
    plus VAT. and shipping


    9230-MIO-422
    Extension RS422-IO

    Extensionboard for EtherSens-devices V1.0 for RS422 (4-wire) Power consumption: 2W
    Quickbestellung INFOMAIL
    by e-mail
    158,00 €
    plus VAT. and shipping


    9230-MIO-232
    Extension RS232-IO

    Extensionboard for EtherSens-devices V1.0 for RS232 (RxD, TxD) Power consumption: 2W
    Quickbestellung INFOMAIL
    by e-mail
    158,00 €
    plus VAT. and shipping


    9230-USB
    Extension USB-port

    USB-port for EtherSens-devices (data storage) Extension for: - DB-backup/restoure-function - CSV-recording Maximum current: 200mA for 5V DC
    Quickbestellung INFOMAIL
    by e-mail
    105,00 €
    plus VAT. and shipping


    accessories:

    9391.1
    24V DC power-supply unit 625mA

    Primary 110V - 240 VAC Euro+USA-plug
    Quickbestellung INFOMAIL
    by e-mail
    59,00 €
    plus VAT. and shipping


    9636-TCPIP
    Patch-cable 3m, Cat5+, shielded

    RJ45 plug <=> RJ45 plug, 1:1
    9636-CROSS
    Cross-cable 3m Cat5+, shielded

    RJ45 plug <=> RJ45 plug, twisted pinning
    9352-WLAN-ANT
    Magnetic base antenna

    for S7-WLAN-Bridge, WLAN-Klemme, EtherSens cable length: 3m
    Quickbestellung INFOMAIL
    by e-mail
    83,00 €
    plus VAT. and shipping


    9636-TCPIP.1M
    Patch-cable 1m, Cat5e, shielded
    RJ45 plug <=> RJ45 plug, 1:1
    Quickbestellung INFOMAIL
    by e-mail
    15,00 €
    plus VAT. and shipping


    9230-SD-32
    Micro-SD-card 32GB

    for EtherSens-devices SDHC class 10
    Quickbestellung INFOMAIL
    by e-mail
    27,00 €
    plus VAT. and shipping


    All prices plus costs of delivery, shipping insurance and VAT.
    All prices plus costs of delivery, shipping insurance and VAT.

    264,00 €
    plus VAT. and shipping


    9352-WLAN-ANT
    Magnetic base antenna

    for S7-WLAN-Bridge, WLAN-Klemme, EtherSens cable length: 3m
    Quickbestellung INFOMAIL
    by e-mail
    83,00 €
    plus VAT. and shipping


    9352-LANCON
    S7-LAN connector for Siemens S7 PLC controller

    Network-connection for the S7-200/300/400-PLC +++ S7-adapter PPI/MPI/PROFIBUS +++ Of developer and manufacturer +++ Smallest Ethernet-gateway S7 +++ Network for each S7-PLC +++ Fast commissioning +++ Replacement for CP343-1/443-1
    Quickbestellung INFOMAIL
    by e-mail
    423,00 €
    plus VAT. and shipping


    9230-LTE
    Extension LTE-modem

    LTE-modem-board for EtherSens-devices Send/receive of SMS-messages Communication from/into internet Power consumption: 6,5W
    Quickbestellung INFOMAIL
    by e-mail
    264,00 €
    plus VAT. and shipping


    9230-EI2C-3.3V
    Extension with ext. galv. separated I2C 3.3V

    Extension-board for EtherSens-devices with galvanic separated external I2C-connector for 3.3V Power consumption: 2W
    Quickbestellung INFOMAIL
    by e-mail
    117,00 €
    plus VAT. and shipping


    Automatic-mode

    Other downloads

    Extension

    Support-videos