S7-BRIDGE







Online with S7-PLC wo. cables +++ S7-adapter PPI/MPI/PROFIBUS/PN +++ No WIFI-infrastructure +++ Integrated access-point +++ PPI/MPI/DP/PN - LAN - WIFI
Universal LAN/WIFI-S7-Adapter
Also available as a set for universal use: S5/S7-BRIDGE-WIFI-SetsProduct Overview:
Our S7-BRIDGE is the world's smallest gateway to all your controllers .
Through integrated WIFI and Ethernet interface, in the housing of a Profibus plug, a mobile access to all PLC systems is no problem.
Wireless access to the MPI/DP bus with S7-300/400, PPI with S7-200 or Profinet on all S7-1200/1500 controllers is no longer an obstacle, it offers the possibility of Access to all other network components.
At the same time, the system works as a S7 network adapter for programming, remote maintenance and for coupling the different PLCs.
Thus, both HMI devices, e.g. current panel series , as well as any other S7-Ethernet device, be connected directly via S7-TCP-IP via LAN & WIFI.
! parallel access to MPI/PPI/PROFIBUS !
Quite simply from Siemens TIA, Simatic Step7 Manager, MICROWIN and WinCC projects
more...
ARTNR: 9352-S7-WIFI
S7-BRIDGE
EAN number: | 4260363249317 | |
HS-code: | 85423190 | |
Weight: | 0.6 kg |
Alternativen
S7-BRIDGE
Online with S7-PLC wo. cables +++ S7-adapter PPI/MPI/PROFIBUS/PN +++ No WIFI-infrastructure +++ Integrated access-point +++ PPI/MPI/DP/PN - LAN - WIFI

plus VAT. and shipping
S7-LAN connector for Siemens S7 PLC controller Obsolete
Successor: S7-LAN++ connector for Siemens S7 Controller (Art.No: 9352-LANCON++)
Network-connection for the S7-200/300/400-PLC +++ S7-adapter PPI/MPI/PROFIBUS +++ Of developer and manufacturer +++ Smallest Ethernet-gateway S7 +++ Network for each S7-PLC +++ Fast commissioning +++ Replacement for CP343-1/443-1

plus VAT. and shipping
S7-GATE connector with integrated firewall for Siemens S7-PLCs
Smallest S7-PLC-Firewall +++ Controls access to the PPI/MPI/PROFIBUS +++ Of developer and manufacturer

plus VAT. and shipping
S7-LAN++ connector for Siemens S7 Controller
Smallest S7-PLC-Firewall +++ Controls access to the PPI/MPI/PROFIBUS +++ Of developer and manufacturer

plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
Stationary antenna for wall fastening
For S5-/S7-BRIDGE, CONNECT CONNECT-ROUTER cable length: 2,5m for indoor and outdoor use incl. wall holder

plus VAT. and shipping
USB-powercable for 24V DC, max. 3W
USB-plug type A to 2 open braids 24V DC, maximum current: 125mA (for PC 100mA) length: 5m

plus VAT. and shipping
plus VAT. and shipping
Sector antenna for ALF
Sector antenna with 17dBi power gain and bundled radiation. Connection cable optional

plus VAT. and shipping
Beam antenna for ALF
Beam antenna with 17dBi power gain for classic radio link connection cable optional

plus VAT. and shipping
plus VAT. and shipping
Magnetic base antenna for indoor use
For S5-/S7-BRIDGE, CONNECT CONNECT-ROUTER cable length: 1,5m

plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
S7-bus-coupler
Disconnects all signals except differential bus lines Safety for all participants at VIPA 21x-2BM0x and 208-1DP0x

plus VAT. and shipping
Programming adapter S7
PPI-Bus | |||||||||
PPI 9.6 KBit/s - 19.2 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
Multimaster 9.6 KBit/s - 187.5 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
MPI-Bus | |||||||||
19.2 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
187.5 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
1.5 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
Profibus | |||||||||
9.6 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
19.2 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
45.45 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
93.75 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
187.5 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
500 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
1.5 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
3.0 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
6.0 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
12.0 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
Profibus-profile | |||||||||
DP |
x(12)
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
standard |
x(12)
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
universal(DP/FMS) |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
RS 232 | |||||||||
9.6 KBit/s |
x(19)
|
x(19)
|
|||||||
19.2 KBit/s |
x
|
x
|
|||||||
38.4 KBit/s |
x
|
x
|
|||||||
57.6 KBit/s |
x(9)
|
x(9)
|
|||||||
115.2 KBit/s |
x(9)
|
x(9)
|
|||||||
USB | |||||||||
USB 1.1 (6) |
x(1)
|
x
|
x(2)
|
||||||
LAN | |||||||||
10/100BaseTx |
x(7)
|
x
|
x
|
x
|
x
|
||||
WIFI | |||||||||
2.4 GHz |
x
|
||||||||
TeleService operation | |||||||||
with S7-300/400 |
x(14)(18)
|
x(14)(18)
|
|||||||
baud rates at TS-operation directly at the PC | |||||||||
9.6 KBit/s |
x
|
x
|
|||||||
19.2 KBit/s |
x
|
x
|
|||||||
38.4 KBit/s |
x(8)
|
x(8)
|
|||||||
57.6 KBit/s |
x(8)
|
x(8)
|
|||||||
baud rates at TS-operation directly with a modem | |||||||||
9.6 KBit/s |
x
|
x
|
|||||||
19.2 KBit/s |
x
|
x
|
|||||||
38.4 KBit/s |
x
|
x
|
|||||||
57.6 KBit/s |
x
|
x
|
|||||||
115.2 KBit/s |
x
|
x
|
|||||||
HMI | |||||||||
9.6 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
19.2 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
38.4 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
57.6 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
115.2 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
update | |||||||||
firmware-update |
x(10)
|
x(10)
|
x(15)
|
x(15)
|
x(15)
|
x(15)
|
x(15)
|
x(15)
|
x(15)
|
input/online help | |||||||||
keypad |
x
|
x
|
x
|
x(21)
|
x(21)
|
x(21)
|
x(21)
|
||
display |
x
|
x
|
x
|
x
|
x(21)
|
x(21)
|
x(21)
|
x(21)
|
|
PD connections (maximum) | |||||||||
PLCVCOM |
1
|
1
|
1
|
1
|
1
|
1
|
1
|
1
|
|
RFC1006 |
8
|
8
|
32
|
32
|
32
|
||||
AG connections (maximum) | |||||||||
passive subscriber |
1
|
15
|
15
|
15
|
15
|
15
|
15
|
15
|
15
|
active subscriber |
126
|
126
|
126
|
126
|
126
|
126
|
126
|
126
|
126
|
more functions | |||||||||
integrated PLC-firewall |
|
|
x
|
x
|
x
|
||||
display diagnostic-buffer in the webbrowser |
|
|
x
|
x
|
x
|
||||
webserver for configuration |
x
|
x
|
x
|
x
|
x
|
||||
Remote access over existing VPN-channel |
x
|
x
|
x
|
x
|
x
|
||||
Access via existing WLAN-channel |
x
|
x
|
x
|
x
|
x
|
||||
status/control variable |
x
|
x
|
x
|
x
|
x
|
||||
S7 on S7/S5 DB exchange |
x
|
x
|
x
|
x
|
x
|
||||
S5 on MPI DB exchange |
only as S5toMPI
|
||||||||
S7 on MPI (Send/Fetch) |
x
|
x
|
x
|
x
|
x
|
||||
Profinet Gateway |
x
|
x
|
x
|
x
|
x
|
||||
Time in PLC from NTP-server |
x
|
x
|
x
|
x
|
x
|
||||
galvanic separation | |||||||||
to the bus (screen connected through) |
1KV
|
1KV
|
1KV
|
1,5KV
|
1KV
|
1,5KV
|
1,5KV
|
1,5KV
|
1,5KV
|
mounting | |||||||||
wall monuting (with opt. wall mounting-set) |
x
|
x
|
x
|
x
|
|||||
upgrading with | |||||||||
CheapConn+cable |
x
|
x
|
x
|
x
|
|||||
supports | |||||||||
WIN 98 |
x
|
x(3)
|
x
|
x
|
x
|
x
|
x
|
||
WIN 98 SE |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
WIN ME |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
WIN NT |
x
|
x(5)
|
x(5)
|
x
|
x(5)
|
||||
WIN 2000 |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
WIN XP Home (4) |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
WIN XP Professional |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
Vista(32bit) |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
Win7(32bit) |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
Win7(64bit) |
(22)
|
x(23)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
Win8/8.1 |
(22)
|
x(23)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
Win10 |
(22)
|
x(23)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
Win11 |
(22)
|
x(23)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
(1) just with USB-cable plug <-> plug, type A <-> A, item number: 9352.1 (2) just with USB-cable plug <-> plug, type A <-> mini B, item number: 9352.3 (3) only serial communication (4) Siemens Step7 V5.2 and higher dont run with this operationing system (5) USB-communication is only possible with the special driver for Win NT (6) USB 2.0 is backward compatible to 1.1 (7) Cable is designed for direct connection to PC network card socket. It can also be a hub / switch with uplink port or operated at a hub / switch with automatic detection of assignement and adaptation (8) only in combination with the MPI-Speed-driver („continously-active“) (9) Siemens Step7 supports these baud rates only with the MPI-Speed-Utility (10) Update directly with PC or via Tele-Network if the cable is connected to a device of the Tele-Network-family (Tele-Link, Tele-Book or Tele-Professional) (11) only in the mode: MultiMaster-Mode (12) up to a maximum baud rate of 187.5 KBit/s (13) In this transmission, the baud rate is irrelevant, because it communicates via a virtual COM-port. (14) with the use of the TS-adapter / item number: 9350.TS (15) Update directly with PC and TIC-driver (18) Operation requires Step 7 with additional software Tele-Service (TS) from Siemens (19) only at PPI-communication possible (20) Only with TIC-driver (21) with integrated webserver possible (22) No support of Siemens Step7-software possible (23) Only with USB and with TIC-driver |
Product Overview:
Our S7-BRIDGE is the world's smallest gateway to all your controllers .
Through integrated WIFI and Ethernet interface, in the housing of a Profibus plug, a mobile access to all PLC systems is no problem.
Wireless access to the MPI/DP bus with S7-300/400, PPI with S7-200 or Profinet on all S7-1200/1500 controllers is no longer an obstacle, it offers the possibility of Access to all other network components.
At the same time, the system works as a S7 network adapter for programming, remote maintenance and for coupling the different PLCs.
Thus, both HMI devices, e.g. current panel series , as well as any other S7-Ethernet device, be connected directly via S7-TCP-IP via LAN & WIFI.
! parallel access to MPI/PPI/PROFIBUS !
Quite simply from Siemens TIA, Simatic Step7 Manager, MICROWIN and WinCC projects
Thanks to the integrated TIC driver without project changes.
New from firmware version V1.08:
One IP-address for WIFI- and PLC-communication, the device itself recognizes which part of the device you want to access. A very simple thing, no address confusion with different IP-addresses.
Convince yourself of the new and simple functionality. Download the new firmware via the download tab and after the update has been completed, trigger the factory setting in the BRIDGE-interface, the device can now be reached via 192.168.1.56.
Download-Firmware-Datei
TIC-(Totally Integrated Communication)-driver for Step7/TIA-Portal for Win XP/VISTA/7/8/10/11 32/64 bit:
TIC firmware / configuration tool / Step7-/TIA-driver
Features:
- every SIMATIC-S7 (S7-200/300/400) into Network
- Replacement for CP343-1/443-1, connected directly to MPI or Profibus
- with Profibus for S7-300 faster than CP343-1
- fastest installation into Network (less than 3 minutes)
- automatic detection of baudrate
- automatic usement of cyclic bus-parameter-protocols
- no bus-knowledge required / automatic-protocol and baud-rate detection
- download TIC-driver for STEP-7/TIA-Portal
- Programming and visualization at the same time (8 connections at the same time)
- compatible to S7-TCP/IP RFC1006, WinCC (flex), OPC UA with Universal communication Industry 4.0, the IP-S7LINK SDK as well as all common OPC-servers
- no HW-Config change necessary
- no change of PLC-software necessary
- including Classic OPC-DA-Server-lite (max. 100 variables)
- with PG-diagnostic-port (occupied slot with PG-port free again)
- DPV1-master of class 2 and supports all functions that a PG supports:
- Diagnosis, configuration and programming of controllers (via software such as Simatic-Manager, TIA-Portal)
- Diagnosis and configuration of DP-slaves (via software such as Starter)
- active module, no influencing other bus users in the system
- active PUT/GET (in module integrated) replaces expensive CP´s for PLC-couplings
- Supply from S7-PLC or 24V DC external
- CE/EMC compliant design
- standard functions like S7-LAN connector
Applications:
- Operational data collection, SCADA of non-networkable controllers
- KTP-panel to S7-PLC with MPI-/Profibus-interface
- PUT/GET from S7-1500/1200/300/400 (PN-CPU or with ethernet-CP) with specified and unspecified connection
- VPN-remote-maintenance, maintenance of the PLC via the Internet
- cyclic time reading from NTP-server and setting in the connected PLC
- coupling with DB-transfer to S7-LAN, S7-Gateway, S7-CP, S5-LAN++ or also S5-Gateway
- any TCP-device writes/reads DBs in the S7-300/400 controller
- monitor variables in the WebServer without a Step7 programming-package
- analysis option of the connected bus-system with spikes- and errors-counter
- Easiest configuration through intuitive web server operation!
The S7 bridge is designed for fast commissioning.
After the module has been plugged into the bus, just set a a IP address directly via the web interface or use the TIC-Driver directly installed @Siemens Software.
After that, the controllers can already be accessed from the network.
NO WIFI INFRASTRUCTURE REQUIRED,
ACCESS-POINT DIRECTLY INTEGRATED!
- Plug in the module, activate WIFI on the laptop, connect with Bridge-WIFI -> DONE
STEP-7 / TIA / WIN-CC / MICROWIN:
Thanks to the TIC driver, every additional installation outside the Siemens world is eliminated.
The configuration takes place direkt in the PG-PC interface and is thus optimally integrated.
Each network device that speaks RFC1006 S7-TCP / IP, such as HMI devices or PGs can access the module directly.
The adapter can be integrated in the S7 project itself, but does not have to be, so operation is possible without changing the project .
The S7 communication runs directly via S7 TCP / IP and expands every MPI bus / PROFIBUS by a network gateway.
It does not matter which controller type, S7-200 / S7-300 / S7-400 , hang in the fieldbus PLC network.
- Thanks to aktiv PUT / GET , integrated directly in the module, no expensive CP's are required for PLC couplings.
- Supports Banner maintenance via VPN tunnel thanks to fully integrated TCP-IP stack with gateway configuration.
Programming / Adapting / Converting
The S7 bridge can be used directly as a WLAN gateway for PLCs. Program and visualize S7 PLC via WLAN is no longer a problem. Thanks to ext. Power supply also usable as Profinet-WIFI adapter.
The S7 SPS Bridge with all functions is the perfect PLC network adapter for every application.
The S7-Bridge is a reliable and handy S7-WIFI network adapter for every PPI, MPI - PROFIBUS and Profinet .
Its compact design in PROFIBUS connector and its power supply directly from the CPU,
enable a PLC to be connected to the Ethernet in less than 5 minutes.
Bus protocols, including baud rate and HSA, are automatically and automatically detected and set.

Wired or wireless communication (WIFI) via the same adapter with the respective control
Always connected to each other, all made possible by the devices of the BRIDGE-family.

Wired or wireless communication (WIFI) via the same adapter with the respective control
Always connected to each other, all made possible by the devices of the BRIDGE-family.



Supply voltage: | 24V DC +/- 20% |
Power consumption: | 3 watt |
Display: |
Web-Browser 3 status-LEDs (of that 1 double-led) |
Handling/Configuration: |
Web-Browser TIC-Software Configuration-tool |
Interfaces: |
to the PLC:
PPI/MPI/Profibus interface: 9,6 KBd - 12 MBd
to the PD/PC:
PD/diagnosis jack10/100BaseTX RJ45-ethernet jack Antenna-plug RP-SMA(f) (IEEE 802.11 b/g/n) |
Galvanic separation: | 1500V PPI/MPI/Profibus to the PC |
Operating systems: | MS-Windows NT, 2000, XP, Vista / Win7/8/10/11 32/64 Bit |
Protocols: | RFC1006, DHCP, HTTP |
Operating temperature: | 0 - 55°C |
Case: | ABS-plastic case |
Dimensions: | 120 x 43 x 17 mm |
Scope of delivery: |
S7-BRIDGE-module WIFI-stub antenna Power connector 2pins small |
accessories:
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
Stationary antenna for wall fastening
For S5-/S7-BRIDGE, CONNECT CONNECT-ROUTER cable length: 2,5m for indoor and outdoor use incl. wall holder

plus VAT. and shipping
USB-powercable for 24V DC, max. 3W
USB-plug type A to 2 open braids 24V DC, maximum current: 125mA (for PC 100mA) length: 5m

plus VAT. and shipping
plus VAT. and shipping
Sector antenna for ALF
Sector antenna with 17dBi power gain and bundled radiation. Connection cable optional

plus VAT. and shipping
Beam antenna for ALF
Beam antenna with 17dBi power gain for classic radio link connection cable optional

plus VAT. and shipping
plus VAT. and shipping
Magnetic base antenna for indoor use
For S5-/S7-BRIDGE, CONNECT CONNECT-ROUTER cable length: 1,5m

plus VAT. and shipping
plus VAT. and shipping
Patch-cable 0.25m, Cat5e, shielded
RJ45 plug <=> RJ45 plug, 1:1
Cross-cable 3m Cat5+, shielded
RJ45 plug <=> RJ45 plug, twisted pinning
Patch-cable 3m, Cat5+, shielded
RJ45 plug <=> RJ45 plug, 1:1

plus VAT. and shipping
S7-bus-coupler
Disconnects all signals except differential bus lines Safety for all participants at VIPA 21x-2BM0x and 208-1DP0x

plus VAT. and shipping
S7-BRIDGE
Online with S7-PLC wo. cables +++ S7-adapter PPI/MPI/PROFIBUS/PN +++ No WIFI-infrastructure +++ Integrated access-point +++ PPI/MPI/DP/PN - LAN - WIFI

plus VAT. and shipping
S7-LAN connector for Siemens S7 PLC controller Obsolete
Successor: S7-LAN++ connector for Siemens S7 Controller (Art.No: 9352-LANCON++)
Network-connection for the S7-200/300/400-PLC +++ S7-adapter PPI/MPI/PROFIBUS +++ Of developer and manufacturer +++ Smallest Ethernet-gateway S7 +++ Network for each S7-PLC +++ Fast commissioning +++ Replacement for CP343-1/443-1

plus VAT. and shipping
S7-GATE connector with integrated firewall for Siemens S7-PLCs
Smallest S7-PLC-Firewall +++ Controls access to the PPI/MPI/PROFIBUS +++ Of developer and manufacturer

plus VAT. and shipping
S7-LAN++ connector for Siemens S7 Controller
Smallest S7-PLC-Firewall +++ Controls access to the PPI/MPI/PROFIBUS +++ Of developer and manufacturer

plus VAT. and shipping
LAN

smallest simatic S7 ethernet gateway with PD-socket, multifunctional, 1 adapter for all PPI, MPI and Profibus applications
with ext. 24V-connector
easy remote maintenance over internet

S7-cable PPI/MPI/PROFIBUS +++ Ethernet-gateway S7 as cable +++ Network for each S7-PLC +++ Parallel LAN access +++ Ethernet for each S7-PLC
WLAN/WIFI

Service-suitcase for couppling to a PLC over LAN/WLAN incl. all accessories

Over WLAN to PLC and ethernet-communication-modules

S7-adapter PPI/MPI/PROFIBUS +++ including PLC-firewall +++ Of developer and manufacturer +++ Smallest Ethernet-gateway S7 +++ Network for each S7-PLC +++ Fast commissioning +++ Replacement for CP343-1/443-1

S7-LAN++ Connector with integrated firewall for Siemens S7-PLCs
plus VAT. and shipping
plus VAT. and shipping
Magnetic base antenna for indoor use
For S5-/S7-BRIDGE, CONNECT CONNECT-ROUTER cable length: 1,5m

plus VAT. and shipping
plus VAT. and shipping
Automatic-mode
Main downloads
Versionstory
Documentation
- Short instruction S7-BRIDGE
- Example PUT/GET for Simatic-Manager and TIA-portal
- Examples of S5-/S7-coupling (S5-PLC and/or S7-PLC active)
- Information-sheet S7-LAN
- Handbook S5-/S7-BRIDGE
- Short instruction S7-interface (german only)
- Short instruction S7-LAN
- Example of use: Watchdog-option
- Handbook S7-LAN (older version)