Cookies help us in providing our services. By using our services, you agree that we set functionally necessary cookies.
Optional cookies that are used for statistical or marketing purposes will only be set after your consent.

       
OK

CONNECT-options ISO(H1) / OPC-UA - S5/S7-BRIDGE - 2G shutdown 01/2026


for your PLC-components we have following
News / Innovations:



Show in browser

CONNECT ISO(H1) <=> S7-TCPIP - gateway
- Translation S7-TCPIP RFC1006 <=> ISO(H1)
- Each ISO(H1) device has its own IP address.
- Machine network decoupled from company network
CONNECT Protokollumsetzer
(further information => click on picture)

CONNECT OPC-UA <=> S7-TCPIP - Gateway
- Making S7-200/300/400 + LOGO8! + S5-90U-S5-155U OPC UA-compatible
- Every S7 TCP/IP controller can be addressed via OPC UA
- Supports OPC UA Server + Client
CONNECT OPC-UA-Gateway
(further information => click on picture)

Cableless round on the S5/S7 control and ONLINE
Who doesn't know that feeling? Alone on site and need to check for e.g. a door contact. PC is connected to the control ONLINE, but who will activate the door contact now? Who opens and closes the door so that the result can be viewed on the screen?


For S5-90U to S5-155U-controls:
S5-BRIDGE
S5-BRIDGE
(further information => click on picture)


For S7-200/300/400/1200/1500-controls:
S5-BRIDGE
S7-BRIDGE
(further information => click on picture)


2G network shutdown announced for 2028
Mobile network operators Telekom and Vodafone have announced the shutdown of their 2G networks for 2028. If you are currently still using 2G devices, start switching to 4G/5G now.

Planned shutdown dates:
Deutsche Telekom: shutdown expected on 30. Juni 2028
Vodafone: shutdown expected at the end of September 2028
                 Exception: 2G remains available for particularly critical IoT applications
                                    expected by 2030
O2/Telefónica: no shutdown date has been announced yet.
1&1: does not operate its own 2G network; however, Vodafone's 2G network can be used via national roaming, therefore, the Vodafone shutdown date applies.

Further information can be found at the Federal Network Agency. (german language)
S5-LAN++
EtherSens ProSuite LTE with article nr: 9230-MESSI-IO
(further information => click on picture)


New firmware/software version(s):
  • S7-LAN++ V3.01 / S7-LAN V2.67 (over TIC V2.63):
    - Problem fixed with converting HEX to ASCII in the
      module GATEWAY
    - The "Ignore Rack/Slot" field is now hidden when
      "Bus address from TSAP" is active
    - Fixed bug that occurred when using an incoming and
      outgoing gateway-connection simultaneously
    - Fixed bug when saving a device name containing special
      characters
    - Fixed bug in the processing of TCP-retransmissions
      in the update program
  • TIC V2.63:
    - "Ignore Rack/Slot" field is now hidden when
      "Bus address from TSAP" is active


Aroused interest?
write us: verkauf@process-informatik.de


© Process-Informatik Entwicklungsgesellschaft mbH
Im Gewerbegebiet 1, 73116 Wäschenbeuren
D-U-N-S-Nr. 319012092