Diagnosis and analysis PLC async. protocols
Quick and comfortable debugging for the PLC and the bus
S5-DIAG:
• simple connect to the PLC via the PD-interface
• troubleshooting without the need of programming one line
• error report in a clear and plain way
• signal recording possible
• comfortable operation via function keys
• 2 languages selectable (German/English)
• power supply from the PLC
• optional power supply possible, in case PLC has no power sources
PG-FOX:
• listening in, logging and analysing of asynchronous communication protocols
• versions for RS232 / RS422 / RS485 and TTY
• galvanic separation of PC and communication line
• data output in HEX- or ASCII-format
• simple connect to the PLC via the PD-interface
• troubleshooting without the need of programming one line
• error report in a clear and plain way
• signal recording possible
• comfortable operation via function keys
• 2 languages selectable (German/English)
• power supply from the PLC
• optional power supply possible, in case PLC has no power sources
PG-FOX:
• listening in, logging and analysing of asynchronous communication protocols
• versions for RS232 / RS422 / RS485 and TTY
• galvanic separation of PC and communication line
• data output in HEX- or ASCII-format
technical specifications S5-Diag: |
|
supply voltage: |
24V/DC +/- 20% |
power consumption: |
3,5 watt |
display: |
LCD-display |
handling/configuration: |
integrated keypad with function keys |
interfaces: |
to the AG: TTY/20mA current loop |
operating temperature: |
5 - 55°C |
case: |
powder coated metal case |
dimensions: |
187 x 110 x 49 mm |
technical specifications PG-FOX: |
|
supply voltage: |
9V/DC |
power consumption: |
- watt |
interfaces: |
to the AG: depending on the variant: 2 x RS232 2 x RS422 2 x TTY/20mA current loop to the PD/PC: 2 x RS232 |
operating temperature: |
5 - 55°C |
case: |
powder coated metal case |
dimensions: |
130 x 80 x 35 mm |
S5-PLC-diagnosis or signal’s doesn’t come, but why? ![]() Your installation shows an error and the commissioning engineer
isn’t available? No problem, connect S5-DIAG with the PLC, enter reason
of PLC’s malfunction (e.g. O32.5 doesn’t come) and the device lists
the possibilities why the output has not been set. So you’re able to figure
out the problem (e.g. safety door not locked) quickly.
| Logging and analysis of communication data ![]() You want check,why your application can´t communicate with the PLC or why after some time past the communication will be broken? No problem, integrate the PG-FOX-hardware in this communication way and log through the PG-FOX-software on an PC the sended data in the exact time. So, you can later check the date and find a solution of the problem. |
to the order datas
article: | |||||
|---|---|---|---|---|---|
| Art. ID. | name | price | quantity | ||
| 9362-1P | PG-FOX-PLUS RS-232 |
166,- € | |||
| 9362-2P | PG-FOX-PLUS RS-422 |
166,- € | |||
| 9368 | S5-DIAG Hand-held unit incl. connecting-cable |
1253,- € | |||
to the order datas
accessories: | |||||
|---|---|---|---|---|---|
| Art. ID. | name | price | quantity | ||
| 9391.1 | 24V DC power-supply unit 625mA Primary 110V - 240 VAC Euro+USA-plug |
39,- € | |||
| 9362 | PG-FOX-software 16 Bit DOS |
102,- € | |||
| 9362-32 | PG-FOX-software 32 Bit Win95/98/NT/2000/XP |
153,- € | |||
| 9362-U | U-adapter power supply |
51,- € | |||















Downloads