Diagnosis and analysis PLC async. protocols

Quick and comfortable debugging for the PLC and the bus

S5-DIAG:

• simple connect to the PLC via the PD-interface
• troubleshooting without the need of programming one line
• error report in a clear and plain way
• signal recording possible
• comfortable operation via function keys
• 2 languages selectable (German/English)
• power supply from the PLC
• optional power supply possible, in case PLC has no power sources

PG-FOX:

• listening in, logging and analysing of asynchronous communication protocols
• versions for RS232 / RS422 / RS485 and TTY
• galvanic separation of PC and communication line
• data output in HEX- or ASCII-format

technical specifications
S5-Diag:
supply voltage:
24V/DC +/- 20%
power consumption:
3,5 watt
display:
LCD-display
handling/configuration:
integrated keypad with function keys
interfaces:
to the AG:
TTY/20mA current loop
operating temperature:
5 - 55°C
case:
powder coated metal case
dimensions:
187 x 110 x 49 mm


technical specifications
PG-FOX:
supply voltage:
9V/DC
power consumption:
- watt
interfaces:
to the AG:
depending on the variant:
2 x RS232
2 x RS422
2 x TTY/20mA current loop
to the PD/PC:
2 x RS232
operating temperature:
5 - 55°C
case:
powder coated metal case
dimensions:
130 x 80 x 35 mm


S5-PLC-diagnosis or signal’s doesn’t come, but why?

Unbenanntes Dokument
Your installation shows an error and the commissioning engineer isn’t available? No problem, connect S5-DIAG with the PLC, enter reason of PLC’s malfunction (e.g. O32.5 doesn’t come) and the device lists the possibilities why the output has not been set. So you’re able to figure out the problem (e.g. safety door not locked) quickly.
Logging and analysis of communication data

Unbenanntes Dokument

You want check,why your application can´t communicate with the PLC or why after some time past the communication will be broken? No problem, integrate the PG-FOX-hardware in this communication way and log through the PG-FOX-software on an PC the sended data in the exact time. So, you can later check the date and find a solution of the problem.

to the order datas

article:

Art. ID.namepricequantity 
9362-1P PG-FOX-PLUS RS-232
166,- € Quickbestellung INFOMAIL
9362-2P PG-FOX-PLUS RS-422
166,- € Quickbestellung INFOMAIL
9368 S5-DIAG
Hand-held unit incl. connecting-cable
1253,- € Quickbestellung INFOMAIL

to the order datas

accessories:

Art. ID.namepricequantity 
9391.1 24V DC power-supply unit 625mA
Primary 110V - 240 VAC Euro+USA-plug
39,- € Quickbestellung INFOMAIL
9362 PG-FOX-software 16 Bit
DOS
102,- € Quickbestellung INFOMAIL
9362-32 PG-FOX-software 32 Bit
Win95/98/NT/2000/XP
153,- € Quickbestellung INFOMAIL
9362-U U-adapter
power supply
51,- € Quickbestellung INFOMAIL